Centrifugation Requirements for Serum Separator Tube Coagulation-Inducing Blood Collection Tubes

To prepare high-quality serum samples using separation-gel-coated tubes, two critical steps are the complete clotting of the blood and proper centrifugation conditions. For centrifugation, a horizontal rotor in a benchtop centrifuge is required.

2012-03-21


Vibration-damping effect of rubber dampers in high-speed centrifuges

There are two types of shafts used in laboratory high-speed centrifuges. One type has a slender, elongated shaft that is inherently highly flexible, allowing it to automatically self-align.

2012-03-20


A Discussion on the Heat Dissipation Issues of Centrifuges

It’s perfectly normal for laboratory centrifuges to generate a lot of heat during operation. As the machine runs, it consumes electrical energy, which is converted into mechanical energy that drives the centrifuge rotor. A portion of this energy is transformed into heat and dissipated outward, causing the centrifuge components to warm up.

2012-03-17


Lu Xiangyi Centrifuge to Exhibit at the Arab Dubai Test Fair

Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. will exhibit at the Laboratory Equipment Exhibition for Arab Countries.

2012-03-07


Uneven sedimentation in laboratory centrifuges during experiments.

Laboratory centrifuges are widely used in laboratories and serve as an indispensable and powerful tool in biological research techniques involving biomacromolecules, organic macromolecules, subcellular components, proteins, nucleic acids, and more.

2012-03-05


Vibration Reduction Principles and Methods for High-Speed Centrifuges

Vibration in high-speed centrifuges is one of the important indicators for assessing their performance.

2012-03-02


The 67th China International Medical Equipment Fair

Introduction to the 67th China International Medical Equipment (Spring) Fair 2012: The 67th China International Medical Equipment (Spring) Fair 2012 (shortened to CMEF 2012) will be held from April 17 to 20, 2012 at the Shenzhen Convention & Exhibition Center.

2012-02-29


Using a laboratory centrifuge requires familiarity with the functions of each component.

During the design and manufacturing of centrifuges, any imbalance caused by machining deviations in the rotor has been corrected through dynamic balancing tests. However, centrifuges generally have a permissible tolerance for sample loading imbalances.

2012-02-27


When selecting a centrifuge, safety protection measures should be taken into consideration.

Centrifuges are high-speed machines and essential tools for daily experiments; therefore, their quality and operational safety are of utmost importance.