The centrifuge developed by Lu Xiangyi for hospital use features an automatic balancing device.

During centrifugation, the centrifugal force is extremely high. Imbalance can lead to accidents. The Lu Xiangyi centrifuge is equipped with an automatic balancing protection device that ensures balanced operation and prevents malfunctions.

2014-02-26


Negotiation and procurement for the Tianjin high-speed centrifuge and other equipment project

The Teaching Instrument and Equipment Supply Center of the Tianjin Municipal Education Commission is conducting a competitive negotiation procurement for equipment projects, including high-speed centrifuges. Qualified suppliers are invited to participate in the negotiations.

2014-02-26


Causes of Corrosion in Laboratory Centrifuge Rotors

The corrosion of centrifuge rotors is typically caused by two factors: chemical corrosion and stress corrosion.

2014-02-26


The 71st China International Medical Equipment (Spring) Expo

The China International Medical Equipment Fair (CMEF), founded in 1979, is held twice a year—in spring and autumn. After more than 30 years of continuous innovation and self-improvement, it has become the largest exhibition in the Asia-Pacific region for medical devices and related products and services.

2014-02-25


Regular maintenance of centrifuges in use

Before use, place the centrifuge on a stable floor surface and ensure that the unit does not shake. After confirming that peripheral facilities such as the power supply are functioning properly, connect the centrifuge to the power source.

2014-02-24


Reasons Why a Low-Temperature Centrifuge Cannot Cool

There are two possible reasons why the temperature is set to normal but no cooling occurs: (1) Rule out a malfunction of the temperature control panel; (2) Check for a sensor failure.

2014-02-24


Solutions for a Frozen Centrifuge with Failed Temperature Control

Temperature is an important parameter for refrigerated centrifuges; therefore, it is essential to use a refrigeration system to cool the centrifuged samples and maintain the centrifugation environment within a specific temperature range (e.g., 1–10℃).

2014-02-24


Troubleshooting methods for laboratory centrifuges that fail to rotate or fail to reach the set speed.

There are three possible causes: (1) A fault in the power circuit section; (2) A fault in the motor itself; (3) A fault in the speed control section.

2014-02-24


How to Choose the Specifications and Accessories for Medical Centrifuges

Medical centrifuges are commonly used to separate samples from vacuum blood collection tubes. There are two specifications of vacuum blood collection tubes: 5 mL and 7 mL.

2014-02-24


Advantages of centrifuges in the pharmaceutical industry

Our company’s newly developed pharmaceutical centrifuge features excellent adaptability, a high degree of automation, stable and reliable operation, strong process capabilities, excellent corrosion resistance, a pleasant operating environment, comprehensive and reliable safety protection devices, and an aesthetically pleasing design. It fully complies with the GMP standards for pharmaceutical manufacturing.

2014-02-21


< 1...104105106...128 >