Don't let your guard down when it comes to safety awareness for sample separation in laboratory centrifuges.
Release time:
2020-07-13
Overview:
Laboratory centrifuge It’s true that this is the lab’s basic equipment—but you can’t approach its operation with the same mindset you’d use for basic equipment. You’ll have to be fully alert and give it your utmost attention.
Laboratory centrifuges are primarily used for blood separation, virus research, DNA analysis, and drug purification. They separate particles of different densities in solutions and are essential experimental equipment for production and research institutions in fields such as radioimmunoassay, biochemistry, and environmental protection.
Take a look at these separated samples—each one calls for utmost, utmost caution. The primary actors in experimental work are humans, and human factors are the single biggest cause of laboratory safety incidents. Therefore, only by focusing on “people” and using various methods to enhance the safety awareness and competence of laboratory personnel can we effectively reduce safety risks.
During the operation of a centrifuge, numerous potential safety hazards exist. If these potential hazards encounter favorable conditions, they could lead to accidents. Therefore, knowing how to prevent laboratory accidents caused by centrifuges is a skill that every laboratory practitioner must master. In addition to the well-known precautions—such as balancing the samples before centrifugation and ensuring that the centrifuge lid is securely closed before starting the machine—it’s clear that these measures alone cannot guarantee the safe use of a centrifuge. Thus, in addition to these basic precautions, please pay attention to the following points when using a centrifuge:
1. Before use, first check that the outer tube of the centrifuge tube is intact and leak-free, and that there is a rubber pad at the bottom.
2. Transfer the solution to be centrifuged into a suitable centrifuge tube. The volume should not exceed two-thirds of the centrifuge tube’s capacity. Then, place the centrifuge tube into the outer tube.
3. Place the sleeve containing the centrifuge tubes on an electronic balance to achieve balance. If the balance is off, add water between the centrifuge tubes and the sleeve or adjust the amount of contents in the centrifuge tubes until balance is achieved.
Be sure to strictly follow this balancing procedure every time you perform centrifugation. Otherwise, the sample cannot be placed into the centrifuge for spinning. If the balance is off, the centrifuge’s shaft could be damaged during operation, potentially leading to a serious accident. You must be extremely vigilant.
4. Place the balanced centrifuge tubes and sleeves into the centrifuge in pairs, facing symmetrically. Remove any unused empty sleeves and then close the centrifuge lid.
5. Before starting the centrifuge, check the speed control knob to ensure it is in the “0” position. Then, turn on the power switch and slowly adjust the speed control knob to gradually increase the speed. When you want to stop the centrifuge, gently turn the knob back to the “0” position. Only after the centrifuge has come to a complete stop can you open the lid and remove the sample. Under no circumstances should you use your hand to manually stop the centrifuge from rotating, as this could lead to an accident.
6. After use, pour out the water from the sleeve. Remove the rubber pad and invert the sleeve to allow it to dry.
7. When using, you should also pay attention to:
① During centrifugation, if you hear any unusual noises, immediately stop the centrifugation. If a centrifuge tube breaks, replace it with a new one and re-balance before resuming centrifugation.
② When handling centrifuged acidic, alkaline, and corrosive solutions, avoid spilling them into the sleeve. If such a spill occurs, immediately rinse it clean to prevent corrosion of the sleeve.
③ The centrifuge should not be used continuously for too long. After about 40 minutes of operation, it should be allowed to rest for approximately 20 minutes to prevent overheating.
④ The centrifuge should be regularly maintained and inspected. Once a year, check the wear condition of the motor’s brushes and commutator inside the centrifuge. If any damage is found, they should be replaced.
The above is a brief introduction to laboratory centrifuges. If you’d like to learn more about centrifuges, feel free to visit Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. for further information.