Centrifuge balancing technology is easier said than done.
Release time:
2020-07-14
Overview:
Abstract: Balancing! Although it’s just two short characters, it’s actually quite challenging to do. The key is that as long as you’re using a centrifuge, “balancing” is critically important—so important, in fact, that if I had to find a word to describe it, it would be this: Balancing requires the same level of caution as avoiding losing your head.
Centrifuge To ensure balance in the centrifuge tubes, make sure that the weights of the two tubes are exactly the same. If the total volume of water in the two tubes is 60 units, then each tube should contain 30 units. Also, you need to check whether the two centrifuge tubes are identical—that is, whether they’re the same model. If the two tubes are of different models or sizes, even if their weights are the same, their centers of gravity will differ, so they won’t be balanced. Whenever possible, use centrifuge tubes of the same model. Moreover, most modern centrifuges allow for a certain degree of weight difference—but a small difference is acceptable, whereas a large discrepancy is not.
And facing the centrifuge,
What I’m really most afraid of is not being able to balance it out!
Just look at all these exclamation marks and bold, shouting-style text—there’s sheer fear radiating even from the words themselves.
You probably all have some idea of what the centrifuge’s rotational speed is, right?
Typical laboratory centrifuges operate at around less than 8,000 rpm, while high-speed centrifuges can reach speeds of 8,000 to 30,000 rpm—or even higher.
That is to say,
A iron block weighing over ten kilograms is rotating at a speed of tens of thousands of revolutions per minute.
But what is the rotational speed of a chainsaw?
Around 5,000.
So...
This isn't an exaggeration—if a rapidly spinning rotor were to fly out of its housing, it’d instantly become a high-speed blade, with damage potential that’s simply MAX.
The walls could even punch right through you...
Even a low-speed centrifuge, though it can be shut down promptly, can still damage the rotor shaft.
You should know that the most expensive part of a centrifuge is the rotor shaft. The next most expensive component is the horizontal rotor.
What troubles experimental users the most is balancing the horizontal rotor. When balancing, one must not only ensure that the samples within a single basket are symmetrical but also take into account whether the samples in opposing baskets are balanced.
Overall, there are two main points:
1. When placing samples inside a single suspended basket, ensure that the basket’s center of gravity is located at the center point of the basket.
2. When placing samples into the opposite hanging baskets, use the sample placement in one basket as the reference and strictly adhere to the principle of symmetry about the rotor’s center point.
How expensive is it? Let me put it this way: a netizen shared the following:
“That kind of frozen centrifuge—once, it wasn’t balanced properly and ended up damaging the rotor. The boss called after-sales service, and as soon as the customer service rep quoted the price, the boss’s face turned pale... It was the first time I’d ever seen our usually unflappable boss lose his composure like that…”
So, once the spindle gets injured, everyone can just watch the boss perform Sichuan Opera—changing his facial expressions.
When two forces acting on a single point are both zero, their resultant force is also zero—simply put, “0 + 0 = 0.” To illustrate with an example involving five samples, since 5 = 2 + 3, we can balance the setup by arranging three tubes in a equilateral triangle (resultant force = 0) and placing the other two tubes facing each other (resultant force = 0)—thus achieving equilibrium (0 + 0 = 0). Of course, this explanation is for reference only.
In fact, many centrifuges in laboratories today are still the old-fashioned kind and haven't been equipped with automatic stop detection features. Once the rotor isn't properly balanced, it could fly out of the machine—and if the rotor does fly out, it could lead to a serious injury accident.
Therefore, when conducting experiments, we should also develop good habits—whenever possible, use a balance to weigh samples before centrifugation, thereby minimizing damage to the centrifuge and ensuring its safe operation.