Rules for Using a Centrifuge

Release time:

2017-06-06


Overview:

   Centrifuge The applications of centrifuges are becoming increasingly widespread. Here, the editor would like to introduce some information about centrifuges. The working principle of a centrifuge is as follows: A suspension (material) enters the drum through the feed pipe and the screw discharge port. Under the action of the centrifugal force generated by high-speed rotation, solid-phase particles with higher specific gravity deposit on the inner wall of the drum. Meanwhile, spiral blades that move relative to the drum continuously scrape off these deposited solid-phase particles from the drum’s inner wall and push them out through the slag discharge port. The clarified liquid after separation flows out of the drum through openings in the liquid-level regulating plate. The relative motion between the screw and the drum—the differential speed—is achieved via a differential gear, the magnitude of which is controlled by an auxiliary motor. The housing of the differential gear is connected to the drum, its output shaft is connected to the screw assembly, and its input shaft is connected to the auxiliary motor. While the main motor drives the drum to rotate, it also rotates the differential gear housing. The auxiliary motor, via a coupling, controls the rotational speed of the differential gear’s input shaft, enabling the differential gear to transmit torque to the screw at a specific speed ratio, thereby ensuring the continuous separation process of the material by the centrifuge.
  Rules for using a centrifuge:
  1. When the centrifuge is in the pre-cooling state, the centrifuge lid must be closed. After the centrifugation is complete, when removing the rotor, place it upside down on the laboratory bench, wipe dry any remaining water inside the chamber, and leave the centrifuge lid open.
  2. During precooling, the rotor lid can be placed either on the centrifuge’s platform or on the lab bench. Under no circumstances should it be left floating loosely on the rotor without being securely tightened, as an accidental start-up could cause the rotor lid to fly off and lead to an accident!
  3. After tightening the rotor cover, be sure to use your fingers to check for any gaps between the rotor and the rotor cover. If there is a gap, loosen and retighten the cover until you confirm that there are no gaps before starting the centrifuge.
  4. During the centrifugation process, operators must not leave the centrifuge room. If any abnormal situation occurs, operators must not turn off the power (POWER); instead, they should press STOP. Before pre-cooling, operators must complete the centrifuge usage log.
  5. Do not use substandard or counterfeit centrifuge tubes, nor use centrifuge tubes that are aged, deformed, or cracked.
  6. Use last during holidays and in the evening. Centrifuge You may leave only after completing the routine safety inspection.
  7. If the instrument malfunctions or any components are damaged during use, please contact us promptly. Precautions for Using Centrifuges: Currently, electric centrifuges are commonly used in laboratories. Since electric centrifuges rotate at high speeds, it is essential to pay close attention to safety. In particular, you must prevent the centrifuge from moving or even falling off the lab bench during operation due to imbalance or aging of the tube holders. Additionally, ensure that the lid is securely closed; otherwise, vibrations could cause the centrifuge tubes to rupture, sending glass fragments flying around and potentially leading to accidents. Therefore, when using a centrifuge, you must carefully follow these operating procedures.
  (1) The bottom of the centrifuge tube sleeve must be padded with cotton or a test-tube pad.
  (2) If the electric centrifuge makes noise or the machine body vibrates, immediately disconnect the power supply and promptly troubleshoot the issue.
  (3) Centrifuge tubes must be placed symmetrically in the rotor to prevent vibration of the machine. If there is only one sample tube, the other tube should be replaced with an equal mass of water.
  (4) When starting the centrifuge, you must first close the top cover before slowly starting it up.
  (5) After the separation is complete, first turn off the centrifuge. Only after the centrifuge has come to a complete stop may you open the centrifuge lid and remove the sample. Do not use external force to forcibly stop the centrifuge from rotating.
  (6) The centrifugation time is generally 1 to 2 minutes; during this period, the experimenter must not leave to attend to other tasks.
  Centrifuges are widely used in hospital laboratories and are an essential piece of basic equipment; yet, all too often, this fundamental equipment is overlooked. The centrifuge is one of the most commonly used pieces of basic equipment. Centrifuge Separation of serum, precipitation of cellular components, bacterial concentration, PCR testing—these are all essential tools.