How to extend the lifespan of a medical centrifuge—start with everyday small actions.
Release time:
2017-05-24
Overview:
Medical centrifuge As for how to extend the lifespan of a centrifuge, there isn't any substantial technological solution. However, if we adopt reasonable and correct practices in our daily use and pay careful attention to routine maintenance, that in itself constitutes excellent care for the centrifuge!
During operation, the motor of a medical centrifuge requires regular maintenance. Not only does this ensure the equipment runs smoothly, but it also effectively extends the device's service life. So, how should users perform maintenance on their medical centrifuge products? Below, we’ll provide a detailed introduction to the proper methods for using and maintaining medical centrifuges—hoping that this information will be helpful to everyone.
1. When using a medical centrifuge, place it on a stable and sturdy work surface. The base of each centrifuge is equipped with rubber suction feet; thanks to atmospheric pressure and the weight of the instrument itself, it will adhere firmly to the work surface. Large-capacity, low-speed medical centrifuges and high-speed refrigerated medical centrifuges should be placed on a solid, level floor accordingly. Ultra-high-speed medical centrifuges, weighing several hundred kilograms, must be installed on a very solid floor and equipped with dustproof and moisture-proof devices to ensure that the centrifuge chamber maintains a sufficient vacuum for normal operation. Before starting the medical centrifuge, make sure the load is balanced; the smaller the weight discrepancy, the better. Otherwise, severe vibrations may occur, damaging both the rotor and the spindle.
2. Select an appropriate rotor and control its rotational speed. The maximum rotational speed of the rotor should be reduced under the following circumstances: when the rotor’s operating time and number of runs reach their specified service life; when the rotor exhibits localized surface damage or slight corrosion inside the tube holes; when using stainless steel centrifuge tubes, sleeves, thick-walled tubes, or centrifuge bottles; when the average density of the sample exceeds 1.2 g/cm³; or when the rotor is exposed to high temperatures.
3. Before each use, carefully inspect the rotor to ensure there are no foreign objects or dirt inside the holes, so as to maintain balance. The rotor must be kept dry and clean, and must never be subjected to impacts or scratches. If the rotor accidentally falls, it should be examined by X-ray to confirm that there is no internal damage before it can be reused. After each use, the rotor should be soaked and cleaned in warm water (50℃~60℃) containing a neutral detergent, then rinsed thoroughly with distilled water or deionized water. After drying it with a soft cloth, use a hairdryer to further dry it, apply wax, and store it in a dry place.
4. The rotor of the medical centrifuge must be operated only after the centrifuge tubes have been properly placed; running the machine empty is strictly prohibited. Medical centrifuge At startup, set the rotational speed or centrifugal force value to a low setting, and then gradually adjust it to the desired level after the machine has started. After one cycle of operation, be sure to return the rotational speed and centrifugal force to the low setting before starting again. Directly starting the machine at high-speed or high-centrifugal-force settings is prohibited.
5. Centrifuge tubes of various types differ in tensile strength and elongation; they should be selected according to specific requirements. Centrifuge tubes can be made from many different materials, such as polyethylene, cellulose, polycarbonate, and polypropylene. When using these tubes, ensure that the samples, solvents, and gradient materials do not corrode the centrifuge tubes or their cap components. Avoid using centrifuge tubes that are expired, aged, cracked, or already corroded, or use them at reduced speeds if possible. Monitor and limit the number of times plastic centrifuge tubes are used, and pay attention to matching them with the appropriate specifications. During centrifugation, never open the chamber lid, and never allow your hands or foreign objects to come into contact with the rotor or centrifuge tubes while they are rotating.
6. For low-temperature centrifugation samples, first precool an empty rotor at 2000 rpm for a certain period of time. During precooling, maintain the temperature around 0℃. Alternatively, the rotor can be placed in a refrigerator for several hours to precool and kept ready for use. Centrifuge tubes can be directly stored in the refrigerator for precooling.
7. During the centrifugation process, if any abnormal phenomena are detected—such as unusual noises or vibrations—the machine should be immediately stopped and inspected. Do not resume operation until the cause has been identified.
8. During daily use of the medical centrifuge, the horizontal alignment of the main unit should be checked and adjusted every three months. The vacuum pump oil should be replaced after every 500 million revolutions of operation. Every approximately 1,500 hours of use, the bearings in the drive section should be cleaned and lubricated with high-speed grease. The joint between the spindle and the rotor should be regularly greased to prevent rust. When the centrifuge is not used for an extended period, it should be coated with anti-rust oil and wrapped in oilpaper. During regular periods of non-use, the centrifuge should be started at low speed once or twice a month for 0.5 hours each time to ensure that all components remain in good working order.
Having read the above usage and maintenance instructions, are you now... Medical centrifuge We now have a better understanding of how to extend lifespan—feel free to give us a call to learn more!