Desktop centrifuges have made significant strides in terms of versatility and automation.

Release time:

2015-10-16


Overview:

Desktop centrifuge

   Desktop centrifuge Not only have advancements been made in speed-control technology, but significant progress has also been achieved in multifunctionality and automation—for instance, variable-rate acceleration and deceleration, stepwise speed adjustment, direct input of centrifugal force, storage and retrieval of operating procedures, automatic diagnosis of instrument status, provision of comprehensive display of parameter and status information for benchtop centrifuges, and increasingly sophisticated safety protection features. Some of these features not only enhance the performance of centrifuges but also directly influence the quality of separation results—for example, variable-rate acceleration and deceleration as well as programmed speed changes can improve banding centrifugation outcomes and shorten centrifugation times. In earlier models of benchtop centrifuges, control systems were composed of discrete components, resulting in complex circuitry, high costs, and limitations in implementing many functions. With the adoption of microcomputer technology, software can now replace hardware functions or enable functionalities that would otherwise be difficult to achieve with hardware alone—such as program-controlled operation and motor control for benchtop centrifuges. This approach has greatly simplified the hardware architecture while simultaneously making multifunctionality and automation a practical reality. Typically, the core component of a microcomputer-based control system for benchtop centrifuges is a single-chip microcomputer. The hardware system includes: an operator interface, a motor control interface, a temperature control interface, a safety protection and monitoring interface, and a system monitoring module.

  This desktop centrifuge technology primarily uses high-frequency DC chopping to adjust the pulse width modulation ratio, thereby transforming the output voltage and supplying power to the DC motor. Due to the very high switching frequency—typically below 50 kHz—smooth DC current can be obtained simply by relying on the motor’s inherent inductance for filtering, thus overcoming the drawbacks of thyristor-based phase-controlled DC speed regulation. As a result, the rotational speed becomes smoother and the speed-regulation range is wider. Open-loop speed control is the simplest speed-control solution; indeed, even as few as a dozen discrete components or a single integrated circuit can constitute an entire system. For this reason, some low-cost centrifuges still adopt this approach domestically today. However, its main drawback is that it requires manual speed adjustment and cannot precisely control the motor current, resulting in relatively low speed accuracy and limited technological added value. Given the limitations of open-loop speed control, most desktop centrifuges both domestically and internationally now widely employ a dual-loop speed-control scheme that incorporates both current feedback and speed feedback. The key advantages of this approach include automatic speed regulation, rapid acceleration, minimal overshoot in speed, high precision, and current-limiting functionality that prevents damage to motor components caused by overcurrent.

  Although DC speed control has a long history and mature technology, the mechanical commutator switching in DC motors is its fatal flaw, which limits the motor’s speed and introduces interference due to the commutator. It also requires frequent replacement of carbon brushes, thereby restricting early attempts at achieving ultra-high or high speeds. Desktop centrifuge It became necessary to adopt indirect speed-increasing solutions such as gear-based transmission or other methods, which not only increased costs and device size but also reduced service life and reliability. In the late 1970s, foreign high-speed benchtop centrifuges were among the first to adopt variable-frequency drive (VFD) technology, primarily by adjusting the supply frequency to the induction motor to regulate its rotational speed. Since induction motors do not require mechanical commutators, this approach not only eliminates the hassle of replacing carbon brushes but also significantly boosts motor speeds—allowing even ultra-high-speed benchtop centrifuges capable of rotating at over 100,000 rpm to be directly driven, thereby greatly simplifying the structure of benchtop centrifuges.

  The suitable operating temperature for a desktop centrifuge is between 0 and 40°C, with relative humidity below 80%. If the centrifuge is not used for an extended period, disconnect the power supply, plug in the power cord, and turn on the power switch. Place the samples to be separated into centrifuge tubes of equal weight, insert them into the corresponding centrifuge sleeves inside the desktop centrifuge, close the lid, and then turn on the power. Adjust the desired centrifugal speed according to experimental requirements, and subsequently set the required centrifugation time or select the "normally closed" (0N) mode. This instrument is simple to operate, convenient to use, and delivers outstanding centrifugation results.

  The desktop centrifuge is equipped with an acceleration sensor paired with data-processing software to develop an intelligent imbalance detection system. This system can monitor the entire centrifugation process, taking into account the specific characteristics of each rotor’s components. Unlike previous mechanical imbalance-detection systems that relied on measuring the swing amplitude of the shaft—and were effective only during the acceleration phase—this new system can detect imbalances at any rotational speed, even at high speeds, including those caused by broken tubes or sample spills. Furthermore, the system enhances the desktop centrifuge’s inherent resistance to imbalances, which not only improves its robustness but also simplifies operation: when using the rotor, users no longer need to perform strict balancing procedures; visual balancing alone is sufficient. Typically, conventional centrifuges mount the entire motor on vibration-damping elastic supports, such as rubber pads. Desktop centrifuge It also frequently employs flexible shafts for earthquake resistance.