Desktop centrifuges can now be considered the darlings of the market.
Release time:
2015-10-15
Overview:
Abstract: Desktop centrifuges have now become market favorites. Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. has conducted a specialized study on this topic, focusing on functional design and structure and drawing on popular desktop centrifuge models both domestically and internationally. By effectively integrating key technologies and their recent advancements, the company hopes to offer constructive and valuable insights through innovation and reform, building upon the existing technical summaries and comparative analyses of widely used domestic and international models.
As is well known in this era of rapid technological advancement, AC variable-frequency drive systems will gradually replace DC speed control systems. The speed-regulating system is the core component of benchtop centrifuges, consisting of three major elements: control, power drive, and motor—primarily responsible for controlling the motor’s rotational speed. Throughout the development of centrifuges, DC speed control has played an indispensable role. Its key features include excellent starting and braking performance, a wide speed-regulation range, simple structure, low cost, and relatively mature theoretical and practical foundations. Consequently, before the 1980s, DC speed control was widely adopted in centrifuges and remains in use today, undergoing continuous improvements. For instance, efforts have been made to enhance the wear resistance of DC motor commutators and carbon brushes, thereby extending the service life of the motor and increasing the interval between carbon-brush replacements in benchtop centrifuges.
Thyristor-phase-controlled DC speed regulation is a classic DC speed-control scheme that features a simple structure and mature technology. It basically meets the requirements for speed control in centrifuges and thus enjoys widespread application both domestically and internationally. Its main drawbacks include poor rectifier waveform, significant current ripple, and a tendency to experience current interruption under light loads. To maintain continuous current flow in the DC motor, a bulky smoothing inductor must be added, which increases the system's complexity and weight. Desktop centrifuge the size and weight. After the 1980s, with the development of fully controlled power devices such as power transistors and field-effect transistors, switching power conversion technology gradually found its way into DC speed-regulation systems for centrifuges—for example, in the German Eppendorf 5410 and 5402 centrifuges. This technology primarily employs high-frequency DC chopping to adjust the duty cycle of the pulses, thereby varying the output voltage and supplying power to the DC motor. Due to the very high switching frequency—typically below 50 kHz—smooth DC current can be achieved simply by relying on the motor’s inherent inductance for filtering, thus overcoming the drawbacks of thyristor-based phase-controlled DC speed regulation. As a result, the rotational speed becomes smoother, and the speed-regulation range is wider.
Open-loop speed control is the simplest speed-control scheme for desktop centrifuges; indeed, a system can be assembled using as few as a dozen discrete components or even a single integrated circuit. For this reason, some low-priced centrifuges still employ this approach in China today. Its main drawbacks are that it requires manual speed adjustment, cannot regulate the motor’s current, and suffers from relatively low speed accuracy and limited technological added value. Given the limitations of open-loop speed control in desktop centrifuges, most centrifuges both domestically and internationally now commonly adopt a dual-loop speed-control scheme that features both current feedback and speed feedback. The primary advantages of this dual-loop approach include automatic speed regulation, rapid acceleration, minimal overshoot in rotational speed, high precision, and current-limiting functionality that prevents motor damage due to overcurrent.
Although DC speed control boasts a long history and mature technology, the mechanical commutator in DC motors remains their fatal weakness, severely limiting motor speed and introducing interference due to the commutator. Moreover, the commutator requires regular replacement of carbon brushes, which compelled early high-speed or ultra-high-speed centrifuges to adopt indirect speed-increasing solutions—such as gear-based transmission—or other alternative methods. These approaches not only increased costs and device size but also reduced service life and reliability. In the late 1970s, foreign manufacturers first introduced variable-frequency drive (VFD) technology into high-speed benchtop centrifuges, primarily by adjusting the motor speed through changing the supply frequency of induction motors. Since induction motors do not require mechanical commutators, this innovation not only eliminates the hassle of replacing carbon brushes but also significantly boosts motor speed. Even ultra-high-speed benchtop centrifuges capable of reaching speeds exceeding 100,000 rpm can now be directly driven, greatly simplifying the overall structure of the centrifuge.
Since the 1990s, nearly all product lines from major overseas centrifuge manufacturers have adopted variable-frequency drive (VFD) technology. Whether it’s ultra-high-speed, high-speed, or low-speed centrifuges, China has now included desktop centrifuges in its key technological攻关 programs, and several manufacturers have already launched next-generation desktop centrifuges. Depending on the type of AC motor used, VFD technology varies accordingly. Currently, there are three main types of motors commonly employed in desktop centrifuges. These motors offer a braking and acceleration/deceleration rate that is twice as fast as comparable centrifuges; however, at present, the most widely used and most mature technology remains... Desktop centrifuge 。