What has always been emphasized regarding the application of centrifuges?
Release time:
2021-12-20
Overview:
Centrifuge The application has consistently emphasized that the appropriate centrifuge should be selected based on the experimental purpose and experimental requirements.
Whether you choose high-speed, low-speed, mini, or large-capacity depends entirely on your own experimental needs.
For example, the separation and purification of common plasmid DNA require a centrifuge, and different experimental methods call for different types of centrifuges.
Detailed explanation as follows:
I. Bacterial Culture and Collection
Inoculate the DH5α strain containing the plasmid pBS onto LB solid medium (containing 50 μg/ml Amp), and incubate at 37°C for 12–24 hours. Using a sterile toothpick, pick a single colony and inoculate it into 5 ml of LB liquid medium (containing 50 μg/ml Amp). Incubate at 37°C with shaking for approximately 12 hours until the late logarithmic growth phase.
II. Rapid and Small-Scale Extraction of Plasmid DNA
The small-scale plasmid DNA extraction method is highly effective for preparing small amounts of partially purified plasmid DNA from large-scale transformants. These methods share common characteristics: they are simple and rapid, allow simultaneous processing of large sample volumes, and yield DNA of a certain degree of purity, sufficient to meet the requirements of restriction enzyme digestion and electrophoresis analysis.
(—) Boiling Method:
1. Transfer 1.5 ml of culture medium into a centrifuge tube and centrifuge at 4°C using a microcentrifuge at 12,000 g for 30 seconds. 2. Discard the supernatant and invert the tube onto blotting paper for a few minutes to allow any remaining liquid to drain completely.
3. Resuspend the bacterial pellet in 120 ml of STET solution and vortex to mix thoroughly.
4. Add 10 ml of freshly prepared lysozyme solution (10 mg/ml) and vortex for 3 seconds. 5. Place the centrifuge tube into a boiling water bath, and immediately remove it after 50 seconds.
6. Centrifuge at 4°C using a microcentrifuge at 12,000 g for 10 minutes.
7. Use a sterile toothpick to remove bacterial debris from the centrifuge tube. 8. Take 20 ml for electrophoresis analysis.
[Note] 1. For Escherichia coli, a single colony can be picked directly from a solid culture medium and subjected to boiling extraction to obtain plasmid DNA.
2. In the boiling method, the addition of lysozyme is subject to certain limitations; at high concentrations, the bacterial lysis effect反而 becomes less effective. Sometimes, different lysozymes can also exhibit bacteriolytic activity.
3. The plasmid DNA extracted may contain RNA, but the RNA does not interfere with subsequent experiments such as restriction enzyme digestion, subcloning, and ligation reactions.
(2) Small-scale DNA purification system
This small-scale DNA purification system can rapidly and efficiently extract plasmid DNA, with the entire process taking only 15 minutes. The extracted plasmids can be directly used for DNA sequencing, restriction enzyme analysis, in vitro transcription, and other applications.
The reagents and columns included in this system can be used to separate and purify 50 samples of plasmid culture solutions, each ranging from 1 to 3 ml. The reagents comprise: 10 ml of cell suspension, 10 ml of cell lysis buffer, 10 ml of neutralization buffer, 50 ml of IZARD small-volume DNA purification resin, 50 ml of column wash solution (add 95% ethanol to a final volume of 120 ml before use), and 50 micro-columns.
1. Centrifuge 1–3 ml of overnight-cultured cell suspension at 4°C using a benchtop high-speed centrifuge at 12,000 g for 1–2 minutes.
2. Remove the supernatant, resuspend the bacterial cells in 200 μl of cell suspension, mix thoroughly, and transfer the suspension into a centrifuge tube. 3. Add 200 μl of cell lysis buffer, invert the centrifuge tube several times until the solution becomes clear and translucent.
4. Add 200 μl of neutralizing solution and invert the centrifuge tube several times.
5. Centrifuge at 4℃ at 12,000 g for 5 minutes, and transfer the supernatant into a new centrifuge tube. 6. Add 1 ml of a small amount of DNA purification resin, and invert the centrifuge tube several times to ensure thorough mixing.
7. Take a disposable syringe, remove the plunger, and connect the syringe barrel to the microcolumn. Using a pipette, transfer the above-mentioned mixture into the syringe barrel, then gently push the plunger to introduce the mixture into the microcolumn. 8. Disconnect the syringe from the microcolumn, remove the plunger, and reconnect the syringe barrel to the microcolumn. Add 2 ml of column wash solution, then gently push the plunger to allow the column wash solution to enter the microcolumn.
9. Remove the microcolumn and place it into a centrifuge tube; centrifuge for 2 minutes to remove the column wash solution from the microcolumn.
10. Place the microcolumn into a new centrifuge tube, add 50 μL of TE (or water) to the microcolumn, let it stand for 1 minute, and then centrifuge at 12,000 g using a benchtop high-speed centrifuge at 4°C for 20 seconds. 11. Discard the microcolumn and store the plasmid DNA in the centrifuge tube at 4°C or -20°C in a refrigerator.
The above is a detailed explanation of how to select different centrifuges for the separation and purification of various plasmid DNAs. Therefore, when purchasing a centrifuge, it’s important to communicate extensively with the centrifuge manufacturer and choose a model that best suits your needs, thus avoiding waste of resources.