Are you familiar with the various types and separation methods of high-speed centrifuges?
Release time:
2018-12-07
Overview:
High-speed centrifuge It gets its name from its high rotational speed; in fact, its performance and structure are quite similar to those of conventional centrifuges. Due to its high rotational speed, the rotor has higher requirements than that of ordinary centrifuges—particularly in terms of material, where titanium alloys and aluminum alloys are commonly used. Similarly, the centrifuge tubes themselves are made of specific materials: they are rigid polyethylene plastic products with caps. These centrifuges are widely used for collecting microorganisms, cellular debris, cells, large organelles, sulfate precipitates, and immunoprecipitates, among other substances.
1. By structure, they can be classified into: desktop high-speed centrifuges and vertical high-speed centrifuges (floor-standing high-speed centrifuges).
2. By capacity, they can be classified as: micro-volume high-speed centrifuges, small-capacity high-speed centrifuges, and large-capacity high-speed centrifuges.
3. By size, they can be classified as: micro high-speed centrifuges, small high-speed centrifuges, and large high-speed centrifuges.
4. By temperature control, centrifuges can be categorized into: refrigerated high-speed centrifuges (low-temperature high-speed centrifuges) and ambient-temperature high-speed centrifuges (refrigerated centrifuges are equipped with a cooling system that can maintain temperatures as low as -20℃; standard centrifuges do not have a cooling system).
5. By centrifugation method, they can be classified into preparative high-speed centrifuges and analytical high-speed centrifuges (analytical centrifuges).
6. By application, they can be categorized as follows: biological high-speed centrifuges, pharmaceutical high-speed centrifuges, chemical high-speed centrifuges, food high-speed centrifuges, starch high-speed centrifuges, oil high-speed centrifuges, dairy high-speed centrifuges, fermentation liquid high-speed centrifuges, and coal tar high-speed centrifuges, among others.
In addition to their diverse classifications, high-speed centrifuges also offer a variety of separation methods:
The first method: differential centrifugation: Gradually increase the centrifugal force, allowing some components in the sample solution to sediment each time.
Differential centrifugation is one of the most commonly used methods. In this method, the centrifuge tube is initially filled with a homogeneous sample solution. After centrifugation at a specific speed for a certain duration, two fractions are obtained: a pellet and a supernatant.
Typically, during the first centrifugation, most of the unwanted large particles are removed by sedimentation. At this stage, the desired components mostly remain in the supernatant. The collected supernatant is then subjected to a higher-speed centrifugation to precipitate the desired particles. The duration of the centrifugation must be carefully chosen so that most of the smaller, undesired particles remain in the supernatant. The resulting pellet and supernatant can undergo further centrifugation until the desired degree of separation and purity is achieved.
Differential centrifugation is characterized by its simple operation, but it does not achieve high separation purity.
The second method: density gradient centrifugation—this technique can simultaneously separate several or all components in a sample, offering excellent resolution.
The third method: Density-gradient centrifugation
Separation is based on the different densities of the particles. During centrifugation, particles migrate to positions where their density matches that of the surrounding medium, forming distinct bands.
The selection of the density gradient must ensure that the gradient’s range encompasses the densities of all particles to be separated. The sample can be placed either on top of the density gradient liquid or uniformly distributed throughout the gradient. After centrifugation, the sample particles will reach their equilibrium positions. Note: Once equilibrium is reached, the separation of particles is determined solely by their densities and is independent of time. At this point, any subsequent changes in centrifugal speed will only affect the relative positions of the bands.
Finally, let me emphasize that no matter how high-quality the instrument you purchase, it still depends on proper daily operation and routine maintenance. Once a malfunction occurs, causing delays in your experiments, the cost will far outweigh any benefits! Above all, safety is paramount when using a centrifuge—uncontrolled centrifugal force can lead to significant damage. Therefore, be sure to pay attention to whether the centrifuge tubes are balanced, whether the rotation speed exceeds the set limit, and whether the rotor shows signs of corrosion.