Actually, understanding the relationship between a centrifuge and its rotor isn't difficult at all.

Release time:

2020-05-08


Overview:

The centrifugal force generated by the high-speed rotation of a centrifuge places stringent demands on the material used for the rotor. Prolonged high-speed rotation can cause irreversible damage to the rotor. Major brands typically use aluminum alloys, while those operating at speeds exceeding 25,000 rpm generally employ carbon fiber or titanium alloys.

   Centrifuge Its origins can be traced back to Germany in 1836—a three-legged centrifuge, marking the first-ever unlocking of the centrifuge’s potential.

  The second-generation unlocking method with more specific applications emerged in 1878 in Sweden, where an invention—the cream separator—was developed to separate cream from milk.

  Next up was an advancement in speed—again, from Sweden—in 1924, when two chemists invented the oil-turbine ultra-high-speed centrifuge.

  Another performance enhancement occurred in 1950, this time in Switzerland, where a centrifuge driven directly by a variable-frequency motor was developed.

  As evidenced by the development history of centrifuges outlined above, high-speed centrifuges have long since taken shape. Today, high-speed centrifuges have become standard laboratory equipment, widely used in scientific research, education, and production sectors across fields such as biology, chemistry, and pharmaceuticals. They are particularly well-suited for the rapid separation and synthesis of trace samples. The centrifugal force generated by high-speed rotation places stringent demands on rotor materials; prolonged high-speed operation can cause irreversible damage to the rotor. Major brands typically use aluminum alloys for their rotors, while those operating at speeds exceeding 25,000 rpm generally employ carbon fiber or titanium alloys.

  However, in recent years, a new type of material has emerged in China for high-speed rotors—lightweight yet incredibly strong. So what’s the story behind it? Let’s take a look at some online research data to see just how robust this material really is.

 Aluminum alloy rotor emphasis comparison table.png

  Each centrifuge has a rated maximum rotational speed, which refers to the speed under no-load conditions. However, the maximum rotational speed varies depending on the type of rotor and the mass of the sample. Different rotors result in different maximum rotational speeds. An imported centrifuge can be equipped with multiple rotors, and a few domestic manufacturers have also successfully developed similar technology, enabling a single machine to serve multiple purposes. Horizontal rotors can reach up to 15,000 rpm/min, while angle rotors typically achieve around 14,000 rpm/min. For specific differences, it’s best to consult the product sales staff and the relevant technical personnel at the manufacturer. Therefore, you should be careful when selecting the rotational speed and ensure that the maximum rotational speed of the chosen centrifuge is higher than your target speed. For example, if your target speed is 16,000 rpm/min, the maximum rotational speed of the centrifuge you select must exceed 16,000 rpm/min.

  Generally, the separation effect depends not so much on the rotational speed as on the centrifugal force. Therefore, even if the rotational speed doesn't meet the required level, as long as the centrifugal force does, you can still achieve the desired experimental results.

  Centrifuge rotors are mainly divided into two types: horizontal rotors—during operation, the rotor basket remains horizontal and is perpendicular to the rotation axis, causing the sample to settle primarily at the bottom of the centrifuge tube; and angle rotors—where the centrifuge container is fixed at a specific angle relative to the rotation axis, causing the sample to settle both at the bottom of the centrifuge tube and along the side walls near the bottom. If you want the separated sample to concentrate at the bottom of the centrifuge tube, choose a horizontal rotor; if you want the sample to concentrate at both the bottom and the side walls near the bottom of the tube, choose an angle rotor.

  There are also special tests or special samples that require specialized rotors, such as large-capacity swinging-bucket rotors commonly used in blood banks, enzyme-linked immunosorbent assay (ELISA) plate rotors, slide rotors, PCR rotors, tube rack rotors, and capillary rotors. Each rotor has fixed specifications that are closely linked to the capacity of the centrifuge—for example, a 36×5ml angle rotor not only determines the type of rotor but also dictates the capacity of the centrifuge. Therefore, selecting the right rotor is extremely important.