Some details and essential accessories for high-speed centrifuges
Release time:
2015-09-02
Overview:
High-speed centrifuge
High-end High-speed centrifuge All of them are equipped with microcomputer control systems, which not only ensure the safe operation of the centrifuge but also enable the automatic completion of operational tasks. Nowadays, many centrifuges feature user-friendly control systems that offer a variety of convenient functions—for example, rotor identification, safety-lock mechanisms, fault-alert notifications, and adjustable acceleration and deceleration curves. In addition to these features, it’s important to pay attention to certain details and essential accessories. The main component of a centrifuge is the motor, which comes in two types: brushed motors and brushless motors. The former has been largely phased out, and most modern centrifuges now use brushless motors. Some of these motors even come with built-in braking functions.
Currently, the rotational speeds of high-speed centrifuges can reach 28,000 to 30,000 r/min. Most centrifuges do not come equipped with vacuum systems; their operation is similar to that of low-speed centrifuges and is remarkably simple. Yet, they offer sufficiently powerful performance to replace some ultracentrifuges, which are characterized by complex operations and require both cumbersome and costly maintenance. With the exception of microcentrifuges designed for small sample volumes, high-speed centrifuges are typically fitted with refrigeration systems to counteract the heat generated by the rotor during high-speed rotation, thereby ensuring the stability of biological samples throughout the centrifugation process. The operating temperature of high-speed refrigerated centrifuges generally ranges from 4 to 6°C, with temperature fluctuations strictly controlled within ±2°C. Some centrifuges are equipped with vacuum systems; however, unlike the high vacuum found in ultracentrifuges, these systems provide only partial vacuum at lower pressure levels. The primary purpose of this partial vacuum is to reduce frictional heating caused by the rotor's interaction with air, minimize rotor rotation noise, and alleviate the load on the motor, thus extending the service life of the drive system.
High-speed centrifuge The primary indicators are maximum rotational speed and maximum rotor capacity. Due to mechanical strength considerations, smaller rotors can achieve higher maximum rotational speeds, whereas larger-capacity rotors have lower maximum rotational speeds. High-speed refrigerated centrifuges typically feature rotors with a maximum capacity of 6 × 500 ml, with a typical maximum rotational speed of 10,000 r/min. In recent years, rotors with a capacity of 6 × 1,000 ml and a rotational speed of approximately 8,000 r/min have emerged, though these are considerably more expensive. High-speed centrifuges capable of generating a relative centrifugal acceleration of 100,000 g—especially those equipped with vertical rotors—can partially replace ultracentrifuges in certain applications. Of course, the centrifugation time required for these high-speed centrifuges tends to be longer than that for ultracentrifuges.
When high-speed centrifuges are running, refrigeration is used, and due to the moisture in the air, frost forms inside the centrifuge chamber. After the machine is stopped, this frost melts into water. Most low-speed, high-capacity centrifuges manufactured abroad lack drain holes, causing water to accumulate steadily in the centrifuge chamber. In such cases, users should remove the rotor themselves and carefully clean out the accumulated water. When reinstalling the rotor, be sure to secure it properly to avoid accidents. During the design and manufacturing process, centrifuges undergo dynamic balancing tests to compensate for imbalances caused by machining errors in the rotor. However, all high-speed centrifuges have a specified allowable imbalance level for sample loading. If the imbalance during sample loading exceeds this allowable limit, although the centrifuge may still run, the resulting unbalanced forces will suddenly impact the bearings and support structure at a frequency of n times per minute, potentially damaging the centrifuge. Therefore, for expensive centrifuges, users should strive to achieve proper balance before starting the centrifugation process—this practice will significantly extend the lifespan of the centrifuge.
When the high-speed centrifuge has completed its spin, wait until the rotor has come to a complete stop before opening the chamber door. Please remove the centrifuge tubes as soon as possible and first check whether the tubes are intact and note the position of the pellet. Quickly decant the supernatant, taking care not to disturb or cloud the pellet. Whether you need the supernatant or the pellet, use clean beakers to collect the supernatant to avoid any mistakes. Be extremely careful when decanting the supernatant to prevent accidentally pouring out the pellet along with it; if you inadvertently mix them together, you’ll have to start over from scratch. If... High-speed centrifuge If there’s a leak in the centrifuge tube, identify the cause and immediately clean the rotor or the centrifuge chamber.
Currently, the rotational speeds of high-speed centrifuges can reach 28,000 to 30,000 r/min. Most centrifuges do not come equipped with vacuum systems; their operation is similar to that of low-speed centrifuges and is remarkably simple. Yet, they offer sufficiently powerful performance to replace some ultracentrifuges, which are characterized by complex operations and require both cumbersome and costly maintenance. With the exception of microcentrifuges designed for small sample volumes, high-speed centrifuges are typically fitted with refrigeration systems to counteract the heat generated by the rotor during high-speed rotation, thereby ensuring the stability of biological samples throughout the centrifugation process. The operating temperature of high-speed refrigerated centrifuges generally ranges from 4 to 6°C, with temperature fluctuations strictly controlled within ±2°C. Some centrifuges are equipped with vacuum systems; however, unlike the high vacuum found in ultracentrifuges, these systems provide only partial vacuum at lower pressure levels. The primary purpose of this partial vacuum is to reduce frictional heating caused by the rotor's interaction with air, minimize rotor rotation noise, and alleviate the load on the motor, thus extending the service life of the drive system.
High-speed centrifuge The primary indicators are maximum rotational speed and maximum rotor capacity. Due to mechanical strength considerations, smaller rotors can achieve higher maximum rotational speeds, whereas larger-capacity rotors have lower maximum rotational speeds. High-speed refrigerated centrifuges typically feature rotors with a maximum capacity of 6 × 500 ml, with a typical maximum rotational speed of 10,000 r/min. In recent years, rotors with a capacity of 6 × 1,000 ml and a rotational speed of approximately 8,000 r/min have emerged, though these are considerably more expensive. High-speed centrifuges capable of generating a relative centrifugal acceleration of 100,000 g—especially those equipped with vertical rotors—can partially replace ultracentrifuges in certain applications. Of course, the centrifugation time required for these high-speed centrifuges tends to be longer than that for ultracentrifuges.
When high-speed centrifuges are running, refrigeration is used, and due to the moisture in the air, frost forms inside the centrifuge chamber. After the machine is stopped, this frost melts into water. Most low-speed, high-capacity centrifuges manufactured abroad lack drain holes, causing water to accumulate steadily in the centrifuge chamber. In such cases, users should remove the rotor themselves and carefully clean out the accumulated water. When reinstalling the rotor, be sure to secure it properly to avoid accidents. During the design and manufacturing process, centrifuges undergo dynamic balancing tests to compensate for imbalances caused by machining errors in the rotor. However, all high-speed centrifuges have a specified allowable imbalance level for sample loading. If the imbalance during sample loading exceeds this allowable limit, although the centrifuge may still run, the resulting unbalanced forces will suddenly impact the bearings and support structure at a frequency of n times per minute, potentially damaging the centrifuge. Therefore, for expensive centrifuges, users should strive to achieve proper balance before starting the centrifugation process—this practice will significantly extend the lifespan of the centrifuge.
When the high-speed centrifuge has completed its spin, wait until the rotor has come to a complete stop before opening the chamber door. Please remove the centrifuge tubes as soon as possible and first check whether the tubes are intact and note the position of the pellet. Quickly decant the supernatant, taking care not to disturb or cloud the pellet. Whether you need the supernatant or the pellet, use clean beakers to collect the supernatant to avoid any mistakes. Be extremely careful when decanting the supernatant to prevent accidentally pouring out the pellet along with it; if you inadvertently mix them together, you’ll have to start over from scratch. If... High-speed centrifuge If there’s a leak in the centrifuge tube, identify the cause and immediately clean the rotor or the centrifuge chamber.