A cell centrifuge is essential equipment for cell culture in biological laboratories.

Release time:

2014-07-02


Overview:

During cell culture, cell centrifugation is typically used to prepare cell suspensions, adjust cell density, wash cells, and collect cells.
  The cell centrifuge plays a rather important role in cell culture in biological laboratories. As a professional manufacturer of centrifuges, Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. would like to provide you with a detailed introduction:
  1. Ultra-clean workbench: Currently, the vast majority of cell laboratories use ultra-clean workbenches to perform sterile operations. These workbenches are characterized by their simple operation, convenient installation, small footprint, and excellent purification performance. There are two main types of ultra-clean workbenches: side-flow (vertical) and outward-flow (horizontal laminar flow). The general working principle involves first filtering indoor air through a coarse filter, then using a centrifugal fan to press the air into a static pressure chamber, and finally passing it through a high-efficiency air filter for fine filtration. The clean airflow thus generated flows through the sterile zone at a uniform velocity across a consistent cross-section, creating a highly clean working environment that is free of dust and microorganisms.
  (1) Side-flow workbench: After air purification, the airflow flows across the workbench surface from either the left or right side toward the opposite side; alternatively, it may flow from top to bottom or from bottom to top toward the opposite side, creating an airflow barrier that keeps the work area sterile. The workbench has a closed structure.
  (2) Outflow Workbench: The purified air flows toward the operator, thus preventing external airflow from entering the work area. The workbench has an open structure; however, performing experiments involving hazardous substances can be detrimental to the operator. Ultra-clean workbenches require regular inspections by the relevant authorities to ensure compliance with cleanliness standards. For ultra-clean workbenches that meet the requirements, the cleanliness level should reach Class 100. Using a particle counter, the number of dust particles with a diameter ≤ 5 μm should not exceed 3.5 particles per liter. The air flow rate should be maintained within the range of 0.75 to 1.0 m³/s. The average bacterial colony count should be less than 1 colony. If necessary, based on the sterility conditions, the filters should be replaced in a timely manner.
  2. Microscope: An inverted microscope is an essential piece of equipment routinely used in cell culture laboratories, primarily for monitoring the daily growth status of cells and detecting any signs of contamination. If funding permits, it is recommended to invest in high-quality phase-contrast microscopes, dissection microscopes, fluorescence microscopes, video recording systems, or time-lapse cinematography equipment equipped with imaging systems, enabling you to capture and document cell growth conditions at any time.
  3. Incubator: Just like cells grown in vivo, cells cultured in vitro also require a constant temperature for survival. The generally optimal growth temperature is 37℃, and the temperature fluctuation should not exceed ±0.5℃. A temperature increase of just 2℃ can become detrimental to cell survival, and when the temperature rises above 40℃, cells will quickly die. Therefore, a precisely temperature-controlled incubator or a CO2 incubator is an ideal choice.
  (1) Constant-temperature incubator: It is recommended to choose a water-jacket or transistor-controlled, self-regulating incubator. These types of incubators offer high sensitivity and relatively stable temperature control. Generally, standard constant-temperature incubators are more affordable; however, their drawback is that they are suitable only for enclosed culture conditions.
  (2) CO2 Incubator: Currently, most cell culture rooms are widely equipped with CO2 incubators. The advantage of CO2 incubators is that they can provide a specific amount of CO2—typically at a concentration of 5%—which is essential for cell culture. They also help maintain a stable pH in the culture medium and are suitable for both open and semi-open culture systems. When using culture flasks, to ensure that the flask remains ventilated with the external environment, the cap should be slightly loosened. To prevent contamination of the cells, the air inside the incubator must be kept clean when using this culture method; therefore, it is necessary to regularly disinfect the incubator with ultraviolet light or alcohol. Additionally, a container filled with sterile distilled water should be placed inside the incubator to prevent evaporation of the culture medium and maintain a relative humidity of 100%.
  (3) Cell culture consumables: Vessels used for culturing cells can include petri dishes, culture plates, or culture flasks. Lebei will not provide a detailed introduction to these in this article; this knowledge will be covered in greater depth in the section on laboratory consumables.
  4. Oven (Drying Oven): Some instruments and vessels used in cell culture must be dried before use; glassware, in particular, requires dry-heat sterilization. During dry-heat sterilization, the oven temperature typically needs to reach above 160°C; a forced-air oven is usually employed. The advantage of this method is that it provides uniform temperature distribution and effective sterilization. However, its disadvantage is that the heating process is relatively slow. When heating, do not first raise the temperature and then start the airflow—instead, begin both the airflow and the temperature rise simultaneously. Once the temperature reaches 100°C, stop the airflow. It is important to avoid burning any paper or cotton wrapping the vessels, as burnt debris could interfere with cell growth. After sterilization, do not open the oven door immediately, as sudden cooling might cause glassware to crack. Instead, wait until the temperature has naturally dropped below 100°C before opening the door.
  5. Water Purification Systems: Cell culture has stringent requirements for water quality. The water used for cell culture, the preparation of cell-culture-related liquids, and the water used for cleaning cell-culture vessels must all undergo rigorous purification treatment beforehand. Currently, a combination of various purification methods is employed to transform ordinary water into either purified water or ultrapure water. These water purification systems are highly flexible and convenient, available in wall-mounted, countertop, and tank-equipped models. They can also be directly connected to dispensing syringes. Moreover, depending on the specific water requirements of different experiments, these systems can be equipped with sterilization functions to effectively remove enzymes such as DNAase, RNAase, and protease. Additionally, there are ultrafiltration-based water purification systems that can efficiently eliminate pyrogens and endotoxins.
  6. Refrigerators: Essential equipment for cell culture laboratories, refrigerators should be dedicated exclusively to cell culture purposes and must not store substances that are volatile, flammable, or otherwise harmful to cells. They must also be kept clean. Typically, refrigerators include standard refrigerators, low-temperature refrigerators, and ultra-low-temperature refrigerators. (1) Standard Refrigerator: Used for storing culture media, physiological saline, Hanks’ solution, and other reagents used in cell culture; it can also be used for short-term preservation of tissue samples. (2) -20°C Low-Temperature Refrigerator and Ultra-Low-Temperature Refrigerator: These are used for storing preparations that require freezing to maintain biological activity and that need to be stored for extended periods, such as enzymes and sera.
  7. Cell Cryopreservation Containers: Commonly used liquid nitrogen containers for cell storage are available in various types and specifications, tailored to different application needs. When selecting a liquid nitrogen container, three key factors should be considered: container volume, ease of access and handling, and the rate of liquid nitrogen evaporation. The capacity of liquid nitrogen containers typically ranges from 25 to 500 liters, enabling storage of approximately 250 to 15,000 1-mL vials. The lowest temperature achievable with liquid nitrogen can reach as low as -196°C; therefore, caution must be exercised during use to avoid frostbite. Since liquid nitrogen is highly volatile, it’s essential to regularly monitor the remaining liquid nitrogen level and replenish it promptly to prevent insufficient supply, which could damage or even kill the cells. Currently, many intelligent cell cryopreservation containers are available on the market. These containers can be equipped with electronic controllers to automate the cryopreservation process, monitor liquid nitrogen levels and sample temperatures, and ensure that sample temperatures remain consistently at the set point. They may also include alarm systems configured to trigger alerts in case of abnormalities such as low liquid nitrogen levels, temperature deviations, battery failures, voltage fluctuations, or power outages. Additionally, these containers often feature a hot-gas bypass system that prevents warm air exceeding -130°C from entering the liquid nitrogen tank, thereby providing more effective protection for samples and preventing temperature increases within the container. Furthermore, some models offer the option of connecting a liquid nitrogen supply tank via a transfer line to continuously replenish the storage tank, ensuring the safety of the samples at all times.
  8. Cell Centrifuge: During cell culture, centrifuges are commonly used to prepare cell suspensions, adjust cell density, wash cells, and collect cells. A standard desktop centrifuge operating at 4,000 rpm is typically sufficient for routine applications. However, if cell sedimentation is required, a centrifugal force of 80–100 G is necessary; excessive centrifugal force can damage cells. Depending on specific requirements, Shanghai Lushangyi offers a variety of advanced centrifuges with additional features, including large-capacity models, temperature-controlled centrifuges, high-speed centrifuges, and low-temperature refrigerated centrifuges.
  9. Balances: Commonly used types include precision balances and analytical balances. The accuracy of analytical balances typically ranges from 0.1 mg, 0.01 mg, to 0.001 mg. Generally, the appropriate balance is selected based on the sample size and precision requirements: for samples weighing more than 100 mg, a balance with an accuracy of 0.1 mg is recommended; for samples weighing between 100 mg and 10 mg, a balance with an accuracy of 0.01 mg is suitable; and for samples weighing 10 mg or less, a balance with an accuracy of 0.001 mg is recommended. Balances should be calibrated regularly; it is advisable to choose balances equipped with automatic calibration functions for easier maintenance. When using a balance, care must be taken to keep it clean and avoid direct contact between corrosive powders or liquids and the weighing platform.
  After thoroughly reading this article, you’ll gain a deeper and more comprehensive understanding of cell centrifuges. Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. welcomes your call for further technical information about cell centrifuges!