The main differences between low-speed refrigerated centrifuges and high-speed refrigerated centrifuges
Release time:
2014-07-04
Overview:
Centrifuges are primarily selected based on two key factors—rotational speed and capacity—depending on the workload. Below, we’ll provide a detailed introduction to several common-sense points about centrifuges:
(1) Rotational Speed: Centrifuges are classified according to their maximum rotational speed into low-speed centrifuges (<10,000 rpm/min), high-speed centrifuges (10,000 rpm/min to 30,000 rpm/min), and ultrahigh-speed centrifuges (>30,000 rpm/min). Each centrifuge has a rated maximum rotational speed, which refers to the speed under no-load conditions. However, the maximum rotational speed can vary depending on the type of rotor and the mass of the sample being processed. For example, if a centrifuge is rated at 16,000 rpm/min, this means that under no-load conditions, the rotor spins 16,000 times per minute. Once a sample is loaded, the actual rotational speed will certainly be lower than 16,000 rpm/min. Different rotors also have different maximum rotational speeds (an imported centrifuge can be equipped with multiple rotors). A horizontal rotor can reach up to 15,000 rpm/min, while an angle rotor typically reaches around 14,000 rpm/min. For specific differences, it’s best to consult the product sales staff and technical personnel from the manufacturer in detail. Therefore, when selecting a centrifuge, you must be careful and ensure that the centrifuge’s maximum rotational speed is higher than your target speed. For instance, if your target speed is 16,000 rpm/min, the centrifuge you choose must have a maximum rotational speed greater than 16,000 rpm/min.
(2) Temperature: Some samples (such as proteins and cells) can be damaged when exposed to high temperatures. In such cases, it’s essential to choose a refrigerated centrifuge, which has a specified temperature range. During high-speed operation, the heat generated by the centrifuge is balanced by its cooling system at a certain temperature—typically, samples subjected to refrigerated centrifugation need to be kept within a temperature range of 3°C to 8°C. The exact temperature achieved also depends on the rotor used. For example, if a centrifuge has a rated temperature range of -10°C to 60°C, when equipped with a horizontal rotor, the temperature during rotation can reach around 3°C; however, if an angle rotor is used, the temperature might only drop to about 7°C. It’s important to consult in detail with the product sales representative and the technical staff at the manufacturer regarding this aspect.
(3) Capacity: How many sample tubes need to be centrifuged each time? And how much capacity is required for each sample tube? These factors determine the total capacity of a centrifuge. Simply put, the total capacity of a centrifuge equals the capacity of each centrifuge tube multiplied by the number of tubes. The total capacity should be matched to the volume of work to be performed.
(4) Rotor: Centrifuge rotors are mainly divided into two types. The horizontal rotor keeps the rotor basket horizontally oriented during operation, at a right angle to the rotation axis; in this configuration, the sample settles and concentrates at the bottom of the centrifuge tube. The angle rotor, on the other hand, positions the centrifuge container at a fixed angle relative to the rotation axis; in this case, the sample settles and concentrates both at the bottom of the centrifuge tube and along the side walls near the bottom. If you want the separated sample to concentrate exclusively at the bottom of the centrifuge tube, choose a horizontal rotor. If you want the sample to concentrate both at the bottom and along the side walls near the bottom of the centrifuge tube, choose an angle rotor.
There are also certain special tests or special samples that require specialized rotors, such as large-capacity swinging-bucket rotors (often used in blood banks), enzyme-linked immunosorbent assay (ELISA) plate rotors, slide rotors, PCR rotors, tube rack rotors, and capillary rotors. Each rotor has fixed specifications that are closely linked to the capacity of the centrifuge—for example, a 36×5 ml angle rotor not only determines the type of rotor but also dictates the capacity of the centrifuge. Therefore, selecting the right rotor is extremely important.
(5) Control System: High-end centrifuges are equipped with microcomputer control systems. These control systems not only ensure the safe operation of the centrifuge but also enable automatic completion of work tasks. Nowadays, many centrifuges feature user-friendly control systems that offer a variety of convenient functions, such as rotor identification, safety lock mechanisms, fault alerting, and customizable acceleration and deceleration curves. In addition to these features, it’s important to pay attention to certain details and essential accessories. The main component of a centrifuge is the motor, which can be either brushed or brushless. The former has been largely phased out, and most modern centrifuges now use brushless motors; some even come with built-in braking functions. Refrigerated centrifuges also differ in their cooling systems—today, environmentally friendly technologies naturally favor fluorine-free refrigeration. Beyond that, noise levels should be considered carefully; whenever possible, choose a centrifuge with lower noise output to maintain a comfortable experimental environment. When it comes to accessories, exercise caution as well—some experiments require specialized centrifuge tubes (for centrifuging toxic samples or when ultra-high-speed centrifugation is needed).
For samples subjected to high-speed centrifugation, the centrifuge tubes must be equipped with appropriate tube sleeves to ensure greater safety. Additionally, there are some specialized sample containers—such as irregular-shaped sample bottles and blood bags—whose specific requirements and accessories need to be carefully considered when selecting a centrifuge; otherwise, normal operation will not be possible.
Based on the information provided above, we can infer that low-speed centrifuges generally offer better temperature control than high-speed centrifuges, or perhaps have a larger capacity. We’d be happy to answer any questions you may have about centrifuges. Our consultation hotline is 021-68113421.