TD5T Automatic Cap-Off Centrifuge
The following content is excerpted from the “TD5T User Manual” and does not constitute medical device advertising.
Category:
Low-speed centrifuge
Automatic cap-removing centrifuge
Keywords:
Detailed introduction
Main technical specifications
1. The vacuum blood collection tube automatically removes the cap, with a cap-removal success rate exceeding 90%.
2. Suitable for vacuum blood collection tubes with diameters of 13 mm and lengths of 75 mm and 100 mm;
3. Large-screen LCD display with a user-friendly interface, making operation simple and convenient.
4. Real-time conversion and setting between RPM and RCF, convenient and quick.
5. Electronic door lock, safe and reliable.
6. It features a special shock-absorbing structure that delivers excellent shock absorption and includes an automatic balancing function.
7. Equipped with multiple protection functions, including unbalance protection, overspeed protection, and door/cover protection.
8. Uses an integral sealing ring made of food-grade silicone rubber, compliant with GMP certification. The centrifuge has obtained U.S. FDA certification.
Main Technical Parameters
Model | TD5T |
Category | Desktop |
Maximum rotational speed | 4000r/min |
Maximum relative centrifugal force | 3030xg |
Maximum number of centrifuge tubes | 84/100 |
Rotational speed accuracy | ±10 rpm |
Time setting range | 1s~99min59s / 1min~99h59min |
Overall machine noise | <65 dB(A) |
Power supply | AC 220V 50Hz |
Overall machine power | 1KW |
External dimensions (L x W x H) | 495mmx620mmx445mm |
Outer packaging dimensions (L x W x H) | 710mmx660mmx490mm |
Net weight | 60kg |
Automatic Hat-Removal Principle Demonstration
After centrifugation is complete, simply pick up the cap-hanging basket. The blood collection tube and tube cap are automatically separated, as shown in the schematic diagram below.
| ![]() | | ||
1. Place the cap-off hanging basket into the vacuum blood collection tube. | 2. Under the action of centrifugal force, the vacuum blood collection tube sinks, and the tube cap separates. | |||
![]() | ![]() | |||
3. Remove the upper-level cap-hanging basket adapter. | 4. Remove the test tube cap—separation is complete. |
Our Services
A comprehensive quality assurance system
Lu Xiangyi always places great importance on her commitments to customers and adheres to the industry’s highest product quality standards.
Standardized service system
Lu Xiangyi’s professional team—we spare no effort to provide users with high-quality products and services.
Collaborative development,共创 future
With your participation and cooperation, Shanghai Luxiangyi will have a brighter future.
Previous
Consult us
If you’re interested in our products, please leave your email address, and we’ll get in touch with you as soon as possible. Thank you!
Related products