The cell centrifugation and separation/purification method can avoid secondary contamination.

Release time:

2019-10-25


Overview:

A cell centrifuge uses centrifugal technology to separate cells. This is a form of substance separation that does not involve a medium, thus avoiding secondary contamination.

   Cell centrifuge Cell separation via centrifugation is a method of substance separation that does not involve a medium, thus avoiding secondary contamination.

  The cell centrifuge employs the centrifugal separation and purification method:

  Centrifugation methods include differential centrifugation and density-gradient centrifugation. Density-gradient centrifugation, in turn, is further divided into rate-zonal density-gradient centrifugation and isopycnic density-gradient centrifugation. After selecting an appropriate method to lyse cells or tissues, the first step typically involves differential centrifugation—this technique separates various cellular components and particles based on the different centrifugal forces generated at different centrifugal speeds. The typical order of differential centrifugation for various organelles and particles is shown in the table below.

  A cell centrifuge is a specialized instrument that uses centrifugal force to separate and precipitate mixed liquids (containing solid particles). Cell centrifuges come in various models, including low-speed and high-speed centrifuges, as well as dual-purpose ultracentrifuges designed for both analytical and preparative applications. Among these, the cell centrifuge is a high-speed centrifuge equipped with a refrigeration system. The temperature inside the centrifuge’s rotor chamber can typically be lowered below zero degrees Celsius. With rotational speeds exceeding 10,000 rpm, cell centrifuges not only possess the performance and structural features of conventional refrigerated centrifuges but also often feature angular rotors made from titanium alloy or aluminum alloy. The centrifuge tubes used are rigid polyethylene plastic containers with caps. These centrifuges are widely employed for collecting microorganisms, cellular debris, whole cells, large organelles, sulfate precipitates, and immunoprecipitates, among other materials. So, what are the key considerations when operating a cell centrifuge?

  Things to keep in mind when operating a cell centrifuge:

  1. The volume of solution loaded into the centrifuge tubes must be appropriate: for stainless steel tubes without caps, fill only up to 2/3; for plastic tubes, fill up to the shoulder. The tube caps must be tightly sealed—leakage is absolutely not allowed. Centrifuging empty tubes can cause them to deform. When using organic solvents with plastic tubes, ensure compliance with applicable regulations.

  2. Centrifuge tubes must be placed in pairs and strictly balanced, with a deviation of less than 0.1 g.

  3. Do not allow the rotor to spin idly without a sample. Always use the handle when placing or removing the rotor to prevent it from slipping and falling. Place the rotor gently and ensure it is securely seated. When unscrewing the handle, hold the handle with your hand and rotate only the rotor itself. The rotor cover must be tightly sealed; centrifugation is prohibited without the cover in place.

  4. During centrifugation, do not open the machine cover, and do not lean on or hold onto the centrifuge. If you hear any unusual noises or notice vibrations, immediately stop the machine.

  5. After using the rotor, it must be promptly removed from the rotor chamber, dried thoroughly, and carefully cleaned inside the tube holes using a hole-cleaning rod. If any solution has spilled, it must be thoroughly cleaned up. Wipe away any condensation inside the rotor chamber, open the door to allow the chamber to air-dry.

  6. Use of the centrifuge requires a reservation and must be logged after use.

  7. Those who have not undergone training and assessment are not permitted to use it.

  8. Select the appropriate rotor and rotational speed; never operate at speeds exceeding the specified limits.

  9. Select an appropriate temperature—typically 4℃—and, except for organic solvents, do not go below zero to avoid freezing, which could damage the centrifuge tubes and rotor.