The Ten Most Common Operations That Easily Lead to Safety Accidents in Low-Temperature Centrifuges

Release time:

2016-02-29


Overview:

The Ten Most Common Operations That Easily Lead to Safety Accidents in Low-Temperature Centrifuges
   In the modern centrifugal industry, Low-temperature centrifuge It’s a device we use quite frequently. However, in actual operation, due to various factors—such as operators performing tasks without receiving proper training, which can lead to safety accidents—it’s essential for users of refrigerated centrifuges to learn how to operate the equipment correctly, ensuring its safe operation and full performance.
  Next, the editor will briefly list the top ten common causes of accidents when using low-temperature centrifuges, hoping that this information will be helpful for your future use.
  1. During the installation of a low-temperature centrifuge, the instrument was forcibly started without first removing the fasteners from the drive system or other components, resulting in shaft breakage and rotor explosion accidents.
  2. During sample loading into centrifuge tubes, an accident occurred because the specific gravity of the original sample was not equal to that of the balancing liquid, causing rotor imbalance.
  3. Failure to balance centrifuge tubes during use is also one of the causes of safety incidents involving low-temperature centrifuges. Users should pay particular attention to this issue during operation.
  4. Before using the centrifuge, the operator failed to promptly obtain information about the relevant centrifuge tubes and used an inappropriate disinfectant, leading to swelling and rupture of the tubes during operation and subsequently causing an accident.
  5. Accidents occur when aluminum alloy centrifuge tube caps and stainless steel centrifuge tube caps are used interchangeably (due to their different specific gravities).
  6. Aging of centrifuge tubes or using centrifuge tubes designed for high-speed centrifuges in ultracentrifuges can cause the tubes to rupture during operation, leading to sample liquid leakage, imbalance, and shaft bending.
  7. Low-temperature centrifuge Improper use and inadequate sterilization of the rubber sealing rings inside centrifuge tube caps and rotor cover rubber sealing rings can lead to aging, cracking, and loss of sealing effectiveness—such as internal fractures from prolonged use or degradation caused by high-temperature sterilization.
  8. In actual operation, if the centrifuge rotor cover is not tightened properly or if the rotor cover and rotor spindle are mistakenly interchanged, causing the screw threads to fail to align correctly, the rotor cover may fly off when the machine is started, leading to a severe shaft failure accident.
  9. The rotor exploded during operation due to improper maintenance after use.
  10. Improper use and inadequate disinfection of the rubber sealing rings inside the rotor tube caps and the rotor cover rubber sealing rings—such as prolonged use leading to internal fractures, or exposure to high-temperature sterilization (e.g., baking in a drying oven)—can cause these rings to age, crack, and lose their sealing effectiveness. As a result, samples may spill out during high-speed operation, causing the rotor to run in an unbalanced state.
  More about Low-temperature centrifuge For more information, we welcome everyone to continue following our company’s website!