Methods and Tips for Selecting a Laboratory Centrifuge

Release time:

2015-03-30


Overview:

Laboratory centrifuges are all equipped with microcomputer control systems. These control systems not only ensure the safe operation of the centrifuges but also enable them to automatically complete their tasks.

Laboratory centrifuge It is an instrument that uses the centrifugal force generated by a rotating rotor to separate substances of different densities and particle sizes from a suspension or emulsion, or to perform analysis concurrently with separation. It has a wide range of applications and is suitable for use in laboratories across various fields, including chemical engineering, food processing, pharmaceuticals, environmental protection, mining, and education.

When selecting a suitable laboratory centrifuge, you should pay attention to the following parameters:

1. Rotational speed

  Centrifuges are classified according to their maximum rotational speed into low-speed centrifuges (<10,000 rpm/min), high-speed centrifuges (10,000 rpm/min to 30,000 rpm/min), and ultrahigh-speed centrifuges (>30,000 rpm/min). Each centrifuge has a rated maximum rotational speed, which refers to the speed achieved under no-load conditions. However, the maximum rotational speed can vary depending on the type of rotor used and the mass of the sample.

For example, if a centrifuge has a rated speed of 16,000 rpm/min, this means that under no-load conditions, the rotor rotates 16,000 times per minute. However, once a sample is added, the actual rotational speed will certainly be lower than 16,000 rpm/min. Different rotors have different maximum speeds. (An imported centrifuge can be equipped with multiple rotors; Lu Xiangyi Centrifuge Manufacturer, a leading domestic centrifuge maker, has successfully developed this technology.) Generally speaking, the separation effect depends more on the centrifugal force than on the rotational speed itself. Therefore, even if the rotational speed doesn't quite meet the specified requirement, as long as the centrifugal force reaches the target level, the desired separation effect can still be achieved during experiments. The formula for calculating centrifugal force is: RCF = 11.2 × R × (r/min / 1000)², where R represents the radius of rotation and r/min represents the rotational speed.

2. Temperature

  Some samples (such as proteins and cells) can be damaged at high temperatures, so it’s necessary to choose a refrigerated centrifuge. All refrigerated centrifuges have a specified temperature range. Laboratory centrifuge During high-speed operation, the heat generated is balanced by the centrifuge’s refrigeration system at a certain temperature (typically, samples subjected to refrigerated centrifugation need to be maintained at 3℃ to 8℃). The exact temperature achieved also depends on the rotor used. For example, if a centrifuge has a rated temperature range of -20℃ to 40℃, when equipped with a horizontal rotor, the temperature can drop to around 3℃ during rotation; whereas with an angle rotor, the temperature might reach approximately 7℃. Ultimately, the specific temperature attained depends on factors such as the set temperature, rotational speed, and the type of rotor used.


3. Capacity

  The total capacity of a centrifuge is determined by factors such as the number of sample tubes required for each spin and the volume capacity of each tube. Simply put, the centrifuge’s total capacity equals the volume capacity of each tube multiplied by the number of tubes. The total capacity should be matched to the scale of the workload.
 
4. Rotor

  Laboratory centrifuge rotors are mainly divided into two types: horizontal rotors—during operation, the rotor basket remains horizontal and is perpendicular to the rotation axis, causing the sample particles to settle at the bottom of the centrifuge tube; and angle rotors—where the centrifuge container is fixed at a specific angle relative to the rotation axis, causing the sample particles to settle both at the bottom of the centrifuge tube and along the side walls near the bottom. If you want the separated sample to concentrate exclusively at the bottom of the centrifuge tube, choose a horizontal rotor; if you want the sample to concentrate both at the bottom and along the side walls near the bottom, choose an angle rotor.

  There are also certain special tests or special samples that require specialized rotors, such as large-capacity basket rotors (commonly used in blood banks), enzyme-linked immunosorbent assay (ELISA) plate rotors, slide rotors, PCR rotors, tube rack rotors, and capillary rotors. Each rotor has fixed specifications that are closely linked to the capacity of the centrifuge—for example, a 36×5 ml angle rotor not only determines the type of rotor but also dictates the centrifuge’s capacity. Furthermore, rotor materials vary widely, including engineering plastics, stainless steel, aluminum alloy, and titanium alloy. The choice of material directly affects the rotor’s price, maximum rotational speed, and service life; therefore, selecting the right rotor is extremely important.
 
5. Control System

  High-end laboratory centrifuges are all equipped with microcomputer control systems. These control systems not only ensure the safe operation of the centrifuge but also enable it to automatically complete its tasks. Nowadays, many centrifuges feature user-friendly control systems that offer a variety of convenient features, such as rotor identification, safety lock functions, automatic balancing, fault-alerting mechanisms, and customizable acceleration and deceleration curves. In addition to these key features, it’s important to pay attention to certain details and essential accessories. The main component of a centrifuge is the motor, which comes in two types: brushed motors and brushless motors. Brushed motors have largely been phased out, and today most centrifuges use brushless motors. Some brushless motors even come with built-in braking functions. As for refrigerated centrifuges, there are differences in their cooling systems; nowadays, environmentally friendly technologies naturally favor fluorine-free refrigeration.

In addition, noise levels should also be taken into account. Whenever possible, choose a centrifuge that generates less noise, as this will help maintain a comfortable experimental environment. When selecting accessories for laboratory centrifuges, caution is essential. Some laboratories use specialized centrifuge tubes—for example, when handling toxic samples or samples requiring ultra-high-speed centrifugation—such tubes must be paired with appropriate tube sleeves to ensure greater safety. Furthermore, there are also certain special sample containers (such as irregular-shaped vials or blood bags). All these details and accessories must be carefully considered when choosing a centrifuge; otherwise, the equipment may not function properly.