Centrifugal separation technology for serum lipoproteins

Release time:

2014-03-04


Overview:

Serum lipoproteins are heterogeneous complexes composed of lipids and certain specific proteins found in the blood.

Due to the differing ratios of lipids to apolipoproteins it contains, its density ranges from 0.96 g/mL or lower to 1.21 g/mL.

In paper electrophoresis, four bands are observed: chylomicrons, very low-density lipoproteins, low-density lipoproteins, and high-density lipoproteins. Each type of lipoprotein can further be subdivided into more subfractions.

Electrophoresis is relatively successful in separating fractions with high apolipoprotein content (HDL and VHDL), whereas centrifugation is more suitable for separating serum lipoproteins of various densities.

 

I. Gradient Materials:

Serum lipoproteins have a lower density; commonly used gradient materials include NaCl, NaI, KBr, and KI, while the commonly used buffer is EDTA.
 
Table 1: Composition and Density of Common Gradient Materials (at 20°C)
  Name Configuration Density (g/ml)
  NaCl 0.196 M 1.006
  NaBr 0.804 M 1.063
  NaBr 2.705M 1.21
  KBr 0.747 M 1.063
  KBr 1.496M 1.21
  NaCl + KBr + EDTA 153 g NaCl + 354 g KBr + 10 ml
  0. 2MEDTA + water to a total volume of 1000 ml 1.35
  NaCl, NaBr
  Solution A: 200 g NaCl + 800 ml water
  Solution B: 400 g NaBr + 600 ml water
  C solution: 11.14 g NaCl + 788.6 ml water (ρ = 1.006 g/ml), 10 ml of A solution + 31.7 ml of B solution
  10 ml of Liquid A + 15.6 ml of Liquid B
  10 ml of Liquid C + 2 ml of Liquid 1.35
  4 ml of Liquid C + 6 ml of Liquid 1.35 1.35
  1.31
  1.063
  1.21

II. Pre-separation:

1. Separation of blood cells from serum:
  Centrifugation parameters: Whole blood, swing-out rotor, 3,000 rpm × 20 min
  Result: The precipitate is blood cells, and the upper layer is serum.

2. Chylomicron Separation: In human plasma from individuals who have fasted for more than 12 hours, the chylomicron content is extremely low. For those who have recently eaten, since their plasma contains high levels of chylomicrons, the plasma should first be centrifuged to remove the chylomicrons.
  Centrifugation parameters: 4 × 10 (g×min), 10°C. Any rotor speed is acceptable.
  Gradient solution preparation: Fill the lower 3/4 of the centrifuge tube with plasma, and the upper 1/4 with 0.
  5M NaCl + 0.3M EDTA, pH 7.4
  Result: The chylomicrons floated to the top and were aspirated.

3. Serum protein separation: Remove globulins, albumin, and other proteins.
  Centrifugation parameters: (2.5–3) × 10⁴ g·hr; applicable to all types of rotors. For example, using a fixed-angle rotor at 70,000 rpm for 6 hours at 10°C.
  Configuration: The tube contains 1/3 serum and 2/3 of a solution with a density of 1.31 g/ml, composed of NaCl plus NaBr; after stirring, the final density is 1.21 g/ml.
  Result: The upper 1/6 of the tube contains serum lipoproteins, while the lower 5/6 contains other proteins.