Relevant information
Handheld Centrifuge | Industry Encyclopedia
Release time:
2023-04-13
Overview:
The handheld centrifuge is one of the most important pieces of equipment in modern biotechnology. It uses centrifugation to separate particles—such as cells and molecules—from biological samples based on their size and density differences, thereby yielding purer and higher-quality biological samples. The handheld centrifuge is easy to operate, requires only small sample volumes, and boasts rapid processing speeds. It has been widely adopted in fields including medicine, bioengineering, food testing, environmental monitoring, pharmaceutical research, and life sciences. The following sections will introduce the key technical aspects of handheld centrifuges.
I. The Principle of Centrifugal Force
The primary function of a centrifuge is to generate centrifugal force, which is based on the principle of centrifugal force. The magnitude of centrifugal force depends on the rotational speed, the radius of rotation, and the density of the substance being centrifuged. Specifically, the faster the rotational speed, the greater the centrifugal force; at a constant rotational speed, the larger the radius of rotation, the greater the centrifugal force; and the higher the density of the substance being centrifuged, the greater the centrifugal force as well. The rotational speed of the centrifuge, the radius of rotation, and the density of the substance loaded into the centrifuge tubes can all be adjusted by the operator.
II. Operating Principle of the Handheld Device
1. Load the sample
The operator needs to pipette the biological sample to be processed into a centrifuge tube and then securely install the tube into the centrifuge. Centrifuge tubes with a diameter of 1.5 mm and a length of 15 mm are commonly used in handheld centrifuges. To ensure that the sample is evenly distributed during centrifugation, only samples of the same type should be placed in each tube, and the marked position on the tube should face toward the center.
2. Set parameters
Both the rotational speed and the duration on the handheld device need to be set to appropriate values. Proper centrifugation parameters ensure effective separation of the target cells, while also optimizing the duration and intensity of centrifugation to minimize cell damage. The centrifuge’s parameters should be determined based on the physical properties of the sample being centrifuged and the intended purpose of the procedure.
3. Centrifugal
After setting the parameters, connect the power supply and start the centrifugation. The centrifugation process should be smooth and uniform. Immediately after centrifugation is complete, stop the centrifuge and remove the centrifuge tubes to prevent secondary contamination or damage to the samples caused by the high-speed rotation.

III. Palm-Sized Operation Techniques
1. Centrifuge tube installation
Centrifuge tubes should be securely fixed in the rotor slot in a completely vertical position, rather than at an angle or in a shaky state. If the centrifuge tubes are not properly secured, immediately stop the centrifugation process and start over to avoid any safety incidents.
2. Power On/Off
When operating the centrifuge, the operator must first set the centrifuge switch to the OFF position, then connect the power supply. Once the desired speed is reached, gently toggle the switch to the ON position to start the centrifuge. After the centrifugation is complete, first set the centrifuge switch to the OFF position, then disconnect the power supply, remove the centrifuge tubes, and take out the centrifuged samples.
3. Centrifugation time
Operators need to set an appropriate centrifugation time based on the type of sample to be centrifuged and the desired rotor speed. A centrifugation time that is too short will affect the centrifugation efficiency, while a centrifugation time that is too long may cause unnecessary damage to the sample.
4. Centrifugal Object Balance
If the sample in the centrifuge tube is unbalanced or contains impurities such as dust, the centrifuge will experience significant shaking, which can adversely affect both stability and the separation of the sample. Therefore, before starting the centrifugation, be sure to ensure that the sample in the centrifuge tube is homogeneous and as balanced as possible.
5. Operations after centrifugation
Immediately after centrifugation is complete, the centrifuge should be turned off and the centrifuge tubes removed to prevent sample contamination or damage. Meanwhile, the samples in the centrifuge tubes should be stored at room temperature or refrigerated as needed. Different handling methods can be adopted depending on the specific experimental requirements, ensuring the quality and reliability of the samples.
IV. On-Hand Maintenance and Precautions
1. Regular maintenance
To ensure the proper functioning of the centrifuge and effective separation of biological samples, it is necessary to perform regular maintenance on the centrifuge. The centrifuge should be kept clean and dry, and its components should be checked regularly to ensure they are in good working order—for example, the centrifuge tubes must be in excellent condition, and special attention should be paid to the rotor and power source. After each use, any residual materials and stains inside the centrifuge should be thoroughly removed to keep it clean.
2. Safe Use
When operating a handheld centrifuge, always pay close attention to safety. At high speeds, the centrifuge generates significant centrifugal force; therefore, you must follow the correct operating procedures, ensure precise positioning of the centrifuge tubes, and check for any foreign objects before starting the centrifugation. After centrifugation, be careful not to allow the sample to come into contact with the exterior surface during handling, and take care when disassembling and cleaning the equipment. Incorrect or improper use can adversely affect and damage your samples; thus, operators must be thoroughly familiar with the specific operating procedures and common-sense precautions. During centrifugation, if any abnormalities or malfunctions occur, immediately stop the operation and repair or replace the relevant components.
3. Store correctly
The centrifuge should be stored in a dry, well-ventilated area and undergo regular maintenance and inspections. The storage period should not be excessively long, and protective measures should be taken when the centrifuge is not used for an extended period. Before use, carefully check the exterior for any signs of damage or deformation. Additionally, always choose products manufactured by reputable manufacturers to avoid purchasing low-quality items.
In summary, the handheld centrifuge is a highly important biotechnology device widely used in fields such as medicine, bioengineering, food testing, environmental monitoring, pharmaceutical research, and life sciences. When using a handheld centrifuge, it is essential to pay attention to operational techniques and maintenance practices to ensure the accuracy and reliability of sample separation.
Keywords: