Medical centrifuge standards are determined based on various parameters.

Release time:

2020-05-11


Overview:

Medical centrifuges can be complex when you look at them closely, yet they’re also quite simple—after all, they’re primarily used in hospital laboratories and are mostly found in hospital clinical laboratories. Moreover, thanks to advances in medical technology today, hospital departments have become highly specialized. As a result, the substances separated by medical centrifuges tend to be relatively uniform, making them easier and more convenient for operators to handle.

   Medical centrifuge It can be complex when you make it complex, but it’s also simple when you keep it straightforward—after all, these devices are primarily used in hospital laboratories and are mostly found in hospital clinical laboratories. Moreover, thanks to advances in medical technology today, hospital departments have become highly specialized. As a result, the substances separated by medical centrifuges used for isolation tend to be relatively uniform, making them easier and more convenient for operators to handle.

  The medical centrifuge is one of the commonly used instruments in the clinical laboratory. It is essential to choose a sealed centrifuge that is safe, boasts excellent performance, carries standard certifications, and incorporates safety features such as lid-locking mechanisms to ensure operator safety. It is crucial to enhance training and assessment for laboratory personnel on biosafety issues, particularly regarding aerosol contamination from centrifuges, which should receive heightened attention from staff. To ensure proper operation, test tubes must be tightly capped and placed securely to prevent sample spillage. During centrifugation, operators should avoid standing too close to the centrifuge; after the centrifuge has come to a complete stop, wait 2–3 minutes before opening the lid to minimize the risk of aerosol exposure to personnel. When necessary, operators may wear masks while using the centrifuge. The surfaces of medical centrifuges should be routinely cleaned and disinfected daily, and the interior should also be wiped down at regular intervals. If, during use, a centrifuge tube becomes unsealed or a test tube breaks, causing liquid to spill and contaminate the centrifuge, immediately disinfect the interior of the centrifuge—especially if there is a potential risk of contamination by hepatitis viruses or Mycobacterium tuberculosis. In such cases, the interior can be wiped down with a neutral glutaraldehyde solution or subjected to whole-unit sterilization using ethylene oxide.

  Medical centrifuges have long been characterized by their simple and straightforward design, ease of operation, and numerous other advantages. However, most medical centrifuge manufacturers continue to rely on traditional production technologies. Moreover, many managers in the medical centrifuge industry show little interest in technological innovation. This has resulted in outdated technology within these companies, hindering their ability to grow and become stronger, and placing them at risk of being phased out. Therefore, domestic medical centrifuge enterprises urgently need to undertake technological reforms. Only by doing so can they stand out in the increasingly fierce competition in the medical centrifuge industry, seize the opportunities presented by the times, and achieve continuous development.

  Medical centrifuges are essential instruments in laboratories, hospitals, and other settings. However, when first coming into contact with them, many people are intimidated by their technical specifications. So how can you determine a centrifuge’s performance or whether it complies with relevant standards?

  The typical parameters of a medical centrifuge include high centrifugal force, high rotational speed, large sample capacity, temperature control accuracy, temperature control range, rotational speed accuracy, noise level range, timing range, power consumption, net weight, external dimensions, and compatible rotor types—among other specifications. If you really don’t understand what these parameters mean, it will be extremely difficult to determine whether the centrifuge complies with relevant standards.

  1. High Rotational Speed: This refers to the high speed at which the centrifuge rotor spins around the axis within the centrifuge chamber. The centrifuge can operate below its maximum rotational speed, but it must never be operated beyond its rated capacity. Otherwise, the rotor could become damaged, and the machine might overheat. Over time, this could significantly shorten the machine’s lifespan and even lead to equipment failure or injury to personnel.

  2. Maximum Processing Capacity: The maximum processing capacity refers to the maximum number of samples that a centrifuge can handle in a single run or operation. When loading samples into the centrifuge, it’s crucial to ensure that the sample volume does not exceed the maximum processing capacity. Otherwise, the rotor and spindle may become deformed.

  3. High Centrifugal Force: Centrifugal force is a type of force that, as we learned in physics, arises from the inertia of objects. Specifically, it’s the force generated when a centrifuge rotor spins around its axis. This force can accelerate the sedimentation rate of various components within a sample or separate molecules of other substances by filtering them through the centrifuge’s mesh screen. The magnitude of centrifugal force is related to gravitational acceleration, rotational speed, and sample volume; at the same rotational speed, different sample volumes will result in different centrifugal forces.

  4. Speed Control (or Regulation) Accuracy: Speed control accuracy refers to the magnitude of deviation that may occur when controlling the centrifuge’s rotational speed or during its operation. When a centrifuge runs at high speeds, some degree of error in its actual rotational speed is inevitable—this is widely acknowledged in medical devices and laboratory equipment. However, there are also established standards for this accuracy; generally, the speed control accuracy deviation is within 50 rpm, though specific requirements may vary depending on the application.

  5. Temperature Control Range: Many experimental procedures have specific temperature requirements for the centrifuge chamber; therefore, the centrifuge must be capable of precisely controlling the temperature within a certain range. This range is referred to as the temperature control range. Typically, during procurement or bidding processes, departments will establish standard specifications and then compare different models accordingly.

  6. Temperature control accuracy: Similar to rotational speed accuracy, temperature control can also deviate due to heat generated during machine operation and the influence of external factors. This deviation is what we refer to as temperature control accuracy. Its typical standard deviation should not exceed 1℃.

  7. Noise Level: Centrifuges often generate noise. In addition to following standard operating procedures for centrifuges, we can also take steps during the selection process by paying attention to the machine’s noise level specification.

  8. Rotor Compatibility: In general, a single centrifuge model can be equipped with multiple rotors, enabling it to serve various purposes or accommodate different experiments. Therefore, we can select several rotors based on our needs for backup purposes.

  9. Power supply wattage: Typically, power supplies have a set of specifications that indicate the voltage and current requirements when the device is running.

  10. Net weight and external dimensions: These pertain to the centrifuge’s appearance, weight, and other such parameters. Generally, there aren’t many specific requirements in this regard, so we won’t go into detail here.

The above is an explanation of medical centrifuges. If you’d like to learn more about medical centrifuges, please stay tuned to Shanghai Luxiangyi Centrifuge Instrument Co., Ltd.