How to Ensure Safe Operation of Centrifuges from Multiple Perspectives
Release time:
2019-10-08
Overview:
Centrifuge The pharmaceutical industry offers great opportunities for those working in this field, but it’s important not to use centrifuges blindly. After all, centrifuges come in various types. Next, let’s briefly introduce the classification of centrifuges.
As is well known, centrifuges are invaluable tools in the pharmaceutical industry for experimental research and development. By rotational speed, they can be classified into low-speed centrifuges, high-speed centrifuges, and ultrahigh-speed centrifuges, among others. By temperature, they can be divided into refrigerated centrifuges and ambient-temperature centrifuges. By capacity, they include microcentrifuges, large-capacity centrifuges, and ultra-large-capacity centrifuges. By design, they can be categorized into benchtop centrifuges and floor-standing centrifuges.
Of course, the reason for such a detailed classification of centrifuges is primarily to ensure the operational safety of centrifuge users. By refining the classification, we can conduct targeted experiments, effectively preventing loss of control during centrifuge operation and thus avoiding significant losses.
In addition to finding the right centrifuge for your needs—as mentioned above—you must also ensure proper operation. Specifically, you should pay attention to whether the centrifuge tubes are balanced, whether the rotation speed exceeds the set value, and whether the rotor shows any signs of corrosion.
Next, taking the desktop low-speed high-capacity centrifuge as an example, let’s go over the key operational points:
1. It is strictly prohibited to allow any liquids or other foreign objects to enter the centrifuge chamber. Otherwise, the main unit may be damaged.
2. The instrument’s casing should be properly grounded to prevent accidents caused by moisture affecting the entire unit.
3. Please do not open the top cover at random when the device is running at high speed.
4. When a setting error occurs, the system will automatically sound an alarm to remind you to reset it.
Here, it’s important to note that if you detect any eccentricity in the centrifuge rotor during use, you should have a qualified technician inspect and repair it. First, remove the rotor, then open the bottom cover to check whether the motor support is misaligned. If so, simply adjust it accordingly.
Even if you’re familiar with the detailed operating procedures for the centrifuge, please still proceed with great care and never let your guard down—for example:
(1) The bottom of the centrifuge tube sleeve must be padded with cotton or a test-tube pad.
(2) If the electric centrifuge makes noise or the machine body vibrates, immediately disconnect the power supply and promptly troubleshoot the issue.
(3) Centrifuge tubes must be placed symmetrically in the rotor to prevent vibration of the machine. If there is only one sample tube, the other tube should be replaced with an equal mass of water.
(4) When starting the centrifuge, you must first close the top cover before slowly starting it up.
(5) After the separation is complete, first turn off the centrifuge. Only after the centrifuge has come to a complete stop may you open the centrifuge lid and remove the sample. Do not use external force to forcibly stop the centrifuge from rotating.
(6) The centrifugation time is generally 1 to 2 minutes; during this period, the experimenter must not leave to attend to other tasks.
These are essential knowledge that every skilled centrifuge operator must master. Having this knowledge not only ensures the safe operation of the centrifuge but also leads to more accurate experimental data!