The high-speed refrigerated centrifuge has solved a major challenge in laboratory experiments.

Release time:

2015-12-23


Overview:

High-speed refrigerated centrifuge
   High-speed refrigerated centrifuge Employ an independent power supply (with phase separation from interference sources) or install a UPS power supply; add an IRC absorption circuit across the relay coil. After implementing these measures, the system has been functioning normally ever since and has not experienced any more crashes. A high-speed refrigerated centrifuge is primarily used to extract the desired components from liquid mixtures. By means of high-speed rotation, the liquids are separated according to their differing densities: denser liquids settle at the bottom, while less dense liquids float on top, thus achieving layering and isolating the pure substances I need. This equipment finds applications in numerous fields, including pharmaceuticals and chemical engineering. The way high-speed refrigerated centrifuges are used in laboratories is generally quite straightforward, and most standard laboratories can easily accommodate them. However, manufacturers of high-speed refrigerated centrifuges would like to remind everyone to ensure that laboratory environments remain clean and well-ventilated.
  High-speed refrigerated centrifuges utilize the powerful centrifugal force generated by the high-speed rotation of the rotor to accelerate the sedimentation rate of particles in a liquid, thereby separating substances with different sedimentation coefficients and buoyant densities within the sample. Primarily used for extracting desired components from liquid mixtures, high-speed refrigerated centrifuges leverage the differing densities of various substances: under high-speed rotation, liquids with higher densities settle at the bottom, while those with lower densities float on top, thus achieving liquid layering and isolating the pure substances we need. These centrifuges find applications in numerous fields, including pharmaceuticals and chemical engineering. In the event of control malfunctions or mechanical system failures, the equipment should promptly detect such issues and trigger an alarm, immediately shutting down all controlled devices to minimize system damage. At the same time, when detecting non-critical faults that do not affect production—such as damaged buttons or abnormal display readings—the system should issue an alarm to alert the operator without halting the production process. The hydraulic press achieves pressure balance through a combined approach of pressurization and depressurization. When the pressure differential (required pressure minus actual pressure) is large, the system employs a strong pressurization mode with zero depressurization output; when the pressure differential is small, it switches to a weak pressurization mode with zero depressurization output; and when the pressure differential is negative (required pressure minus actual pressure is negative), the system adopts a mode where pressurization is set to zero and depressurization is enabled. High-speed refrigerated centrifuge Theoretically, this process is relatively simple; however, due to the phenomenon of system response lag in actual control operations, the algorithm should be adjusted during on-site commissioning to achieve the most satisfactory control results.
  When substances settle in the medium of a high-speed refrigerated centrifuge, they are accompanied by diffusion. Diffusion is unconditional and absolute. It is inversely proportional to the mass of the substance—thus, the smaller the particles, the more severe the diffusion. In contrast, sedimentation is relative and conditional; it requires external forces to occur. Sedimentation is directly proportional to the weight of the object—hence, the larger the particles, the faster they settle. For particles smaller than a few micrometers—such as viruses or proteins—which exist in solution in a colloidal or semi-colloidal state, it is impossible to observe the sedimentation process using only gravity in a high-speed refrigerated centrifuge. This is because the smaller the particles, the slower their sedimentation rate, while the diffusion phenomenon becomes increasingly pronounced. Therefore, it is necessary to use a centrifuge to generate a powerful centrifugal force, which can overcome diffusion and induce sedimentation in these tiny particles.
  The high-speed refrigerated centrifuge addresses a major challenge in laboratory experiments, yielding significantly improved experimental results for samples. It supports sample volumes ranging from微量 tubes up to a maximum of 4 × 200 ml, features a brushless, maintenance-free variable-frequency motor with a long service life, and incorporates magnetic rotor identification. As a versatile benchtop refrigerated centrifuge, it operates exceptionally smoothly even at its highest speeds. The rotational speed can be precisely adjusted and displayed within a range of 100 to 15,300 rpm. A variety of horizontal and angle rotors are available in different specifications, helping to prevent rotor overspeeding. The microcontroller allows users to set the rotational speed, time, temperature, and centrifugal force. When the rotor is stationary, pre-cooling can be initiated. The unit employs R134a environmentally friendly, fluorine-free refrigerant. High-speed refrigerated centrifuge 20 acceleration and deceleration curves (3k15) and 10 program memory functions. The maximum preset time is 9.59 hours, or continuous operation. Complies with international safety standards, including IEC1010 and ISO9001 quality certification.