A handheld centrifuge is indispensable for PCR experiment partitioning.
Release time:
2021-04-08
Overview:
Handheld centrifuge Also known as a mini centrifuge, it is used for microscale experiments.
Common applications include:
1. Extract serum from whole blood.
2. Prepare the supernatant from various samples.
3. Rapid settling of the sample.
4. Micro-volume blood cell separation.
5. Microbial sample processing.
6. Perform PCR experiments with partitioned centrifugation.
Take the last experiment as an example,
To understand PCR experimental partitioning, you first need to grasp the concept of aerosols. An aerosol is a colloidal dispersion system formed when tiny solid or liquid particles are dispersed and suspended in a gaseous medium. When gas and liquid surfaces rub against each other—such as during vigorous shaking of reaction tubes, centrifugation in a centrifuge, opening the cap of PCR products after amplification, pipetting samples, or repeatedly aspirating and dispensing samples with a pipette—the process can generate aerosols that lead to contamination.
In summary, to obtain reliable experimental results, the PCR reaction requires strict laboratory partitioning.
The standard setup requires three separate zones: a reagent and consumables storage and preparation area, a sample handling and preparation area, and an amplification and detection area. Each zone must be completely isolated from the others. The laboratory shall implement controlled airflow: the pre-amplification and post-amplification areas should have independent ventilation systems. The post-amplification area must maintain negative pressure, while the other areas remain at atmospheric pressure, thereby preventing amplified products from entering the pre-amplification areas.
Methods for preventing contamination in PCR experiments:
(1) Reasonably separate laboratory areas: Divide the laboratory into distinct zones or rooms for different steps, including sample processing, preparation of PCR reaction mixtures, PCR amplification cycles, and identification of PCR products. Special attention should be paid to ensuring that sample processing and PCR product identification are strictly separated from other steps. Ideally, the laboratory should be divided into the following zones: ① Sample Processing Zone; ② PCR Reaction Mixture Preparation Zone; ③ PCR Amplification Cycle Zone; ④ PCR Product Identification Zone. All laboratory supplies and pipette tips used in these zones must be dedicated exclusively to their respective tasks. Before starting any experiment, the laboratory should be thoroughly disinfected with ultraviolet light to eliminate any residual DNA or RNA.
(2) Pipette: Contamination of pipettes is a noteworthy issue. Accidental aspiration of samples or template nucleic acids into the pipette or adhesion of such materials to the pipette tip during operation can serve as a serious source of contamination. Therefore, extreme care must be taken when adding samples or aspirating template nucleic acids. Aspiration should be performed slowly, ideally in one continuous motion, and repeated aspiration should be avoided to prevent cross-contamination or aerosol generation.
(3) Pre-mixing and aliquoting PCR reagents: All PCR reagents should be aliquoted in small volumes. If possible, the PCR reaction mix should be prepared in advance, aliquoted into small portions, and stored at -20℃. This practice helps reduce the number of repeated pipetting steps and minimizes the risk of contamination. In addition, PCR reagents and PCR reaction mixes should be stored separately from samples and PCR products; they should not be placed in the same ice box or refrigerator.
(4) To prevent contamination by operators, disposable gloves, pipette tips, and small centrifuge tubes should be used only once.
(5) Establish appropriate positive and negative controls. The positive control should use the lowest detectable amount of standard pathogen nucleic acid that can produce an amplification band. Also, pay attention to the possibility of cross-contamination. Each reaction must include a reagent control tube without any template as well as a corresponding sample that does not contain the nucleic acid to be amplified as a negative control.
(6) Reduce the number of PCR cycles—stop as soon as the PCR product reaches the detection threshold.
(7) Select high-quality centrifuge tubes to prevent sample leakage and the entry of foreign nucleic acids. Before opening a centrifuge tube, first spin it briefly to centrifuge any liquid adhering to the tube walls and cap down to the bottom of the tube. When opening the tube, do so gently to avoid splashing the liquid inside.
The main instruments and equipment used in PCR experiments include refrigerators, ultra-clean benches, pipettes, mixers, balances, and handheld centrifuges. In addition to being dedicated for PCR use, pipettes and balances should also be regularly calibrated. Reagent aliquoting should be performed in an ultra-clean bench. The amplification reaction mixture must be prepared using molecular biology-grade reagents. After preparation, the reagents should undergo quality inspection: first, to check for contamination; second, to verify the amplification efficiency of the reagents.