How to Turn Lab Centrifuge Training into a Helper
Release time:
2021-02-04
Overview:
Laboratory centrifuge Used correctly, it’s a “helper”; used incorrectly, it’s a “killer”!
Take, for example, plant DNA extraction: The principle is to remove the plant cell wall, cell membrane, plastids, mitochondria, and chloroplasts, leaving behind only the nucleus—the DNA we need.
Plant tissues and cells are typically disrupted by mechanical grinding. Since plant cell homogenates contain various enzymes—especially oxidoreductases—which can adversely affect DNA extraction, it is necessary to add antioxidants or strong reducing agents (such as β-mercaptoethanol) to the extraction buffer to reduce the activity of these enzymes. Grinding in liquid nitrogen facilitates easier tissue disruption and minimizes the activity of various enzymes during the grinding process.
Sodium dodecyl creatine, cetyltrimethylammonium bromide—commonly referred to as CTAB—and sodium dodecyl sulfate—commonly referred to as SDS—are ionic surfactants that can dissolve cell membrane and nuclear membrane proteins, causing the dissociation of nuclear proteins and thereby freeing the DNA. When organic solvents such as phenol and chloroform are added, they denature proteins and induce phase separation in the extract. Since nucleic acids (DNA and RNA) are highly water-soluble, centrifugation allows the removal of cellular debris and most proteins from the extract. Finally, anhydrous ethanol is added to the supernatant to precipitate the DNA. The precipitated DNA is then dissolved in TE solution, yielding a total plant DNA solution.
Although extracting DNA from plant leaves is relatively straightforward—simply use a centrifuge, then identify a specific gene sequence based on the plant species, design primers accordingly, and perform a PCR reaction to amplify that gene—the entire process doesn't actually require many pieces of equipment. The most critical instruments are the centrifuge and the PCR machine.
However, there are many details that need attention here, such as:
Precautions for using a laboratory centrifuge:
1. When the centrifuge is in the pre-cooling state, the centrifuge lid must be closed. After the centrifugation is complete, when removing the rotor, place it upside down on the lab bench, wipe dry any remaining water inside the chamber, and leave the centrifuge lid open.
2. During precooling, the rotor lid can be placed either on the centrifuge’s platform or on the lab bench. Under no circumstances should it be left floating loosely on the rotor without being securely tightened, as an accidental startup could cause the rotor lid to fly off and result in an accident!
3. After tightening the rotor cover, be sure to use your fingers to check that there is no gap between the rotor and the rotor cover. If there is a gap, loosen and retighten the cover until you confirm that there is no gap before starting the centrifuge.
4. During the centrifugation process, operators must not leave the centrifuge room. In the event of an abnormal situation, operators must not turn off the power supply (POWER); instead, they should press STOP. Before pre-cooling, operators must complete the centrifuge usage log.
5. Do not use substandard or counterfeit centrifuge tubes, nor use centrifuge tubes that are aged, deformed, or cracked.
6. The bottom of the centrifuge tube sleeve should be padded with cotton or a test-tube pad.
7. If the electric centrifuge makes noise or the machine body vibrates, immediately disconnect the power supply and promptly troubleshoot the issue.
8. Centrifuge tubes must be placed symmetrically in the rotor to prevent vibration of the machine body. If there is only one sample tube, the other tube should be replaced with an equal mass of water.
9. When starting the centrifuge, you must first close the top cover before slowly turning it on.
10. After the separation is complete, first turn off the centrifuge. Only after the centrifuge has come to a complete stop may you open the centrifuge lid and remove the sample. Do not use external force to forcibly stop the centrifuge from rotating.

Precautions for using a PCR instrument:
(1) The environment in which a PCR instrument is used must be stable. The temperature of the working environment should not be too high or too low; it’s best to use the instrument in an air-conditioned room. Some PCR instruments are equipped with temperature protection features, and they won’t start up if the temperature falls below a certain threshold.
(2) The power supply must be stable; the operating voltage should not fluctuate excessively. Excessive voltage fluctuations can damage electronic components. It is generally recommended to connect the PCR instrument’s power supply to a regulated power supply.
However, it’s important to note that before using either a centrifuge or a PCR instrument, you must carefully read the user manual. If you encounter any problems that you can’t resolve on your own, do not disassemble the equipment arbitrarily. Instead, have the issue addressed by a professional service engineer from the manufacturer who is responsible for after-sales support.