Don't overlook the regular and scheduled maintenance of medical centrifuges.
Release time:
2019-11-01
Overview:
Medical centrifuge In which hospital departments do you often see these? Let me let you in on a secret—actually, they’re found in many departments. For example, the blood-testing department and the urine-testing department both have them, and there are others as well. In short, any department involved in laboratory testing will have them.
Since many hospitals are crowded with people, centrifuges have a very heavy workload, which leads to significant wear and tear on the motors of medical centrifuges.
Considering the issue of frequent use of medical centrifuges mentioned above, we should pay attention to performing regular and timely maintenance and repairs. This step is primarily aimed at prevention.
Prevent what?
1. Prevent failures caused by shutdowns, no rotation, or slow rotation speeds.
2. Prevent accidents from occurring.
Next, let’s take a closer look at the detailed analysis of medical centrifuges. When a medical centrifuge malfunctions—such as failing to start up or running at a slow speed—the first step is to rule out any faults in the power supply system. These faults may include broken power cords, poor contact between plugs and sockets, damaged bearings, short circuits or open circuits in the stator or rotor windings, or even burnt-out components. Another common cause is an open circuit in the brushes—that is, inadequate contact or poor connection between the commutator on the rotor and the brushes. This is because the motors typically used in medical centrifuges are series-wound motors. Such motors consist of two main parts: the stator and the rotor. The stator comprises a centralized fixed magnetic pole made up of an iron core and field windings. The rotor, on the other hand, consists of an iron core, rotor windings, and a commutator. The brushes play a crucial role in connecting the stator windings through the commutator to the rotor windings. In a series-wound motor, the current flows from the power source, passes through the stator field windings, the brushes, and then through the commutator into the rotor windings. From there, it returns via the brushes and stator field windings back to the power source, thus completing the circuit. Both the field windings and the rotor windings are connected in series through the commutator and brushes. Since the current remains constant throughout the circuit, the motor can only operate normally at the desired speed if the series circuit is completely unobstructed. Therefore, it’s clear that the working condition of the brushes directly affects the normal operation of the motor. However, due to factors such as wear and tear, material consumption, or spring failure during the brushes’ contact with the commutator, the brushes can easily become open-circuited and lose contact with the commutator. This is one of the primary causes of centrifuge shutdowns or slow rotation speeds.
Medical centrifuges operate at high speeds during use, so safety must be carefully observed. The following points must be strictly adhered to:
When using a medical centrifuge, place it on a stable and sturdy work surface. The base of each centrifuge is equipped with rubber suction feet that, thanks to atmospheric pressure and the instrument's own weight, ensure it adheres firmly to the work surface. Large-capacity low-speed centrifuges and high-speed refrigerated centrifuges should be placed on a solid, level floor accordingly. Ultracentrifuges, which can weigh several hundred kilograms, must be installed on a very solid floor and equipped with dustproof and moisture-proof devices to ensure that the centrifuge chamber maintains a sufficient vacuum for normal operation. Before starting the centrifuge, make sure the load is balanced; the smaller the weight discrepancy, the better. Otherwise, severe vibrations may occur, damaging both the rotor and the spindle.
Additionally, it’s important to note that medical centrifuges use centrifuge tubes of varying tensile strengths and elongation properties; these should be selected according to specific requirements. Centrifuge tubes can be made from a variety of materials, such as polyethylene, cellulose, polycarbonate, and polypropylene. When using these tubes, ensure that the samples, solvents, and gradient materials do not corrode the tubes or their cap assemblies. Avoid using centrifuge tubes that are expired, aged, cracked, or already corroded, or reduce their operating speed if used under such conditions. Monitor and control the number of times plastic centrifuge tubes are used, and pay attention to ensuring proper matching of tube specifications. During centrifugation, never open the chamber lid of a medical centrifuge, and never allow your hands or foreign objects to come into contact with the rotor or centrifuge tubes while they are rotating.
The above is a brief introduction to medical centrifuges. If you’d like to learn more about medical centrifuges, be sure to communicate and exchange information with manufacturers of medical centrifuges.