The automatic cap-removal centrifuge is making waves in the centrifuge market thanks to its distinctive "cap-removal" feature.

Release time:

2016-09-26


Overview:

Automatic cap-removing centrifuge

   Automatic cap-removing centrifuge It’s a new product that has become the darling of the centrifuge industry in recent years. Although its primary application scope isn't as broad as that of high-speed centrifuges, low-speed centrifuges, refrigerated centrifuges, medical centrifuges, laboratory centrifuges, large-capacity centrifuges, or mini-centrifuges, the automatic cap-removal centrifuge’s key feature lies precisely in its “cap-removal” capability—a feature that the previously mentioned, more widely used centrifuges simply cannot achieve. This is one of the main reasons why the automatic cap-removal centrifuge has gained such popularity and acclaim within the industry.
  The automatic cap-removal centrifuge is specially designed for professional use in hospitals, blood banks, radioimmunoassay laboratories, nuclear medicine facilities, and other similar institutions. It integrates automatic cap removal and centrifugation into a single, seamless process, completely resolving the longstanding challenge of cap removal during the separation of vacuum blood collection tubes—a problem that has long plagued hospital workflows. This centrifuge represents today’s most innovative, advanced, and highly efficient separation equipment. As a standard laboratory centrifuge, the automatic cap-removal centrifuge finds wide application in various fields including clinical medicine, biochemistry, immunology, blood banks, pharmaceutical research, education, and production. Most high-speed centrifuges employ water-cooled electric motors as their drive units; these motors transmit power through a gearbox equipped with gears that achieve ultra-high rotational speeds of tens of thousands of revolutions per minute, which are then transmitted to the rotor via a flexible shaft. To minimize noise and vibration generated during high-speed operation, the gears are typically made from non-metallic materials. During operation, the gears require thorough cooling and adequate oil lubrication to extend their service life and reduce component wear.

Image of an automatic decapping centrifuge                                                     
After centrifugation is complete, when removing the rotor from the automatic decapping centrifuge, place it upside down on the lab bench, wipe dry any remaining water inside the chamber, and leave the centrifuge lid open. The rotor cap should be placed either on the platform of the decapping centrifuge or on the lab bench—under no circumstances should it be left floating loosely on top of the rotor, as an accidental startup could cause the rotor cap to fly off, leading to a serious accident! After tightening the rotor cap, be sure to use your fingers to check that there is no gap between the rotor and the cap. If you detect any gaps, loosen and retighten the cap until you confirm that there is a perfect seal before starting the centrifuge. Automatic cap-removing centrifuge During the centrifugation process, operators must not leave the room where the automatic decapping centrifuge is located. In the event of an abnormal situation, operators must not turn off the power supply (POWER); instead, they should press the STOP button. Only high-quality centrifuge tubes approved for use may be employed; counterfeit or substandard tubes are strictly prohibited. Furthermore, centrifuge tubes that are aged, deformed, cracked, or otherwise of inadequate quality must not be used. On holidays and during evening hours, the last staff member to use the centrifuge must conduct a routine safety inspection before leaving. If the instrument malfunctions or components become damaged during operation, promptly contact our Keda Centrifuge manufacturer—under no circumstances should you attempt to disassemble the instrument yourself.
  When the automatic rotor-removal centrifuge is not used for an extended period or during maintenance, the main power plug should be disconnected. If the main power plug remains connected and the switch button is pressed, although the machine appears to have stopped, it will still be energized, which can easily lead to safety accidents—especially during maintenance. When installing or removing the rotor, handle these operations with care to avoid bending the rotor shaft. To remove the rotor from the shaft, first unscrew the locking bolt, then the rotor can be separated from the shaft and taken out. When the rotor is not in use, it should be removed from the centrifuge chamber and promptly cleaned and dried with a neutral detergent to prevent chemical corrosion. Store the rotor in a dry, well-ventilated place. The automatic rotor-removal centrifuge must not be cleaned or washed with non-neutral detergents, nor should the rotor be dried using electric hot-air blowers. The conical surface inside the rotor’s central hole should be lightly coated with a small amount of lubricant for protection. When using rotors for medical centrifuges, always double-check that the rotor number setting is correct. An incorrect rotor number setting could result in the rotor being operated at excessive speeds or failing to reach the required centrifugal speed—particularly... Automatic cap-removing centrifuge Over-speed operation could lead to a catastrophic accident involving rotor rupture—absolutely do not be careless or complacent.