Factors Affecting Centrifuge Experimental Results and Key Considerations for Selection

Release time:

2012-05-19


Overview:

When selecting a precision centrifuge, we need to consider the following five aspects. For ordinary centrifuges, it’s sufficient to choose based on two factors—rotational speed and capacity—depending on the workload.
  When selecting a precision centrifuge, we need to consider the following five aspects. For ordinary centrifuges, it’s sufficient to choose based on two factors—rotational speed and capacity—depending on the workload. Below, we’ll provide a detailed introduction to the key considerations when purchasing a precision centrifuge:
  
  (1) Rotational Speed: Centrifuges are classified according to their maximum rotational speed into low-speed centrifuges (<10,000 rpm/min), high-speed centrifuges (10,000–30,000 rpm/min), and ultrahigh-speed centrifuges (>30,000 rpm/min). Each centrifuge has a rated maximum rotational speed, which refers to the speed under no-load conditions. However, the actual maximum rotational speed may vary depending on the type of rotor and the mass of the sample being processed. For example, if a centrifuge is rated at 16,000 rpm/min, this means that under no-load conditions, the rotor will spin 16,000 times per minute. Once a sample is added, the actual rotational speed will certainly be lower than 16,000 rpm/min. Different rotors also have different maximum rotational speeds (an imported centrifuge can be equipped with multiple rotors). A horizontal rotor can typically reach up to 15,000 rpm/min, while an angle rotor can usually achieve around 14,000 rpm/min. For specific differences, it’s best to consult in detail with the product sales personnel and the technical staff from the manufacturer. Therefore, when selecting a centrifuge, you must be careful and ensure that the centrifuge’s maximum rotational speed is higher than your target speed. For instance, if your target speed is 16,000 rpm/min, the centrifuge you choose must have a maximum rotational speed greater than 16,000 rpm/min.
  
  (2) Temperature: Some samples (such as proteins and cells) can be damaged when exposed to high temperatures. In such cases, it’s essential to choose a refrigerated centrifuge, which has a specified temperature range. During high-speed operation, the heat generated by the centrifuge is balanced by its cooling system at a certain temperature—typically, samples subjected to refrigerated centrifugation need to be maintained at 3°C to 8°C. The exact temperature achieved depends on the rotor used. For example, if a centrifuge has a rated temperature range of -10°C to 60°C, when equipped with a horizontal rotor, the temperature during rotation can reach around 3°C; however, if an angle rotor is used, the temperature might only drop to about 7°C. It’s important to consult in detail with the product sales representative and the technical staff at the manufacturer regarding this aspect.
  
  (3) Capacity: How many sample tubes need to be centrifuged each time? And how much capacity is required for each sample tube? These factors determine the total capacity of a centrifuge. Simply put, the total capacity of a centrifuge equals the capacity of each centrifuge tube multiplied by the number of tubes. The total capacity should be matched to the workload.
  
  (4) Rotor: Centrifuge rotors are mainly divided into two types. The horizontal rotor keeps the rotor basket in a horizontal position during operation, perpendicular to the rotation axis; samples settle and concentrate at the bottom of the centrifuge tube. The angle rotor, by contrast, keeps the centrifuge container at a fixed angle relative to the rotation axis; samples settle and concentrate both at the bottom of the centrifuge tube and along the side walls near the bottom. If you want the separated samples to concentrate exclusively at the bottom of the centrifuge tube, choose a horizontal rotor. If you want the samples to concentrate both at the bottom of the tube and along the side walls near the bottom, choose an angle rotor.
  
  There are also special tests or special samples that require specialized rotors, such as large-capacity basket rotors (often used in blood banks), enzyme-linked immunosorbent assay (ELISA) plate rotors, slide rotors, PCR rotors, tube rack rotors, and capillary rotors. Each rotor has fixed specifications that are matched to the capacity of the centrifuge—for example, a 36×5 ml angle rotor not only determines the type of rotor but also dictates the capacity of the centrifuge. Therefore, selecting the right rotor is extremely important.
  
  (5) Control System: High-end centrifuges are equipped with microcomputer control systems that not only ensure safe operation but also enable automatic completion of work tasks. Nowadays, many centrifuges feature user-friendly control systems, such as rotor identification, safety lock functions, fault-alerting mechanisms, and customizable acceleration and deceleration curves. In addition to these features, it’s important to pay attention to certain details and essential accessories. The main component of a centrifuge is the motor, which can be either brushed or brushless. The former has been largely phased out, and most modern centrifuges now use brushless motors; some even come with built-in braking functions. Refrigerated centrifuges also differ in their cooling technologies—today, environmentally friendly refrigeration methods naturally employ fluorine-free cooling systems. Beyond this, noise levels should also be considered; whenever possible, choose a centrifuge with lower noise output to maintain a comfortable experimental environment. When it comes to accessories, caution is key. Certain experiments require specialized centrifuge tubes—for instance, when handling toxic samples or samples needing ultra-high-speed centrifugation—such tubes must be used with appropriate tube sleeves for enhanced safety. Additionally, there are other specialized sample containers (such as irregular-shaped vials or blood bags). All these details and accessories must be carefully considered when selecting a centrifuge; otherwise, normal operation may be compromised.