Detailed Analysis of Surge Faults in Laboratory Centrifuge Equipment

Release time:

2012-02-05


Overview:

The air intake resistance of the refrigerated centrifuge is high, for example, due to a clogged filter or an obstruction at the impeller inlet. Under normal circumstances, during installation and commissioning, surge testing is performed—adjusting the pressure and current via PI tuning—and after memorization, the system avoids high- and low-pressure surges.
  Surge in centrifuges is a killer for these machines, and high-speed refrigerated centrifuges and ultrahigh-speed refrigerated centrifuges are particularly prone to this phenomenon. However, in severe cases, surge can damage components such as the centrifuge rotor. In other words, any external factor that causes the operating point of the refrigerated centrifuge to shift into the surge region—thus separating it from the pipeline network—can trigger surge.
  
  From the perspective of the performance curve of a cryogenic centrifugal compressor, when surge occurs in such a compressor, its operating point invariably enters the surge region. Therefore, severe surge in cryogenic centrifugal compressors is closely related to the characteristics of the connected piping network. In the theoretical operation of cryogenic centrifugal compressors, the following factors can all trigger surge: switching defects in the air separation system; electrical faults or interlock shutdowns that result in the failure to promptly open relief valves or anti-surge valves; failure to promptly open valves leading to the main heat exchanger or molecular sieve adsorber, causing the discharge pressure of the cryogenic centrifugal compressor to rise excessively and sharply steepen the piping network’s characteristic curve. As a result, the operating point of the cryogenic centrifugal compressor rapidly shifts away from its original working range and into the surge region, thereby triggering surge. During the compressor startup process, if the control actions are uncoordinated—such as rapid pressurization accompanied by small inlet guide vane openings—or if the power grid quality is poor (e.g., a drop in grid frequency or an abnormally low voltage), the motor may stall, causing the flow rate of the cryogenic centrifugal compressor to fall into the surge region. Additionally, blockages within the flow passages of the cryogenic centrifugal compressor can occur due to leaks in the cooler or fouling caused by dust accumulation, which roughens the passage surfaces and reduces the cross-sectional area of certain sections.
  
  The air intake resistance of the refrigerated centrifuge is high, for example, due to a clogged filter or an obstruction at the impeller inlet. Under normal circumstances, during installation and commissioning, surge testing is performed—adjusting the pressure and current via PI tuning—and after memorization, the system avoids high- and low-pressure surges.