Have you paid close attention to the “body temperature” of the centrifuge?

Release time:

2016-09-22


Overview:

Centrifuge

   Centrifuge The biggest concern for users is that improper use of centrifuges can lead to accidents. The most obvious sign of this is overheating during instrument operation—pay close attention: it’s “overheating.” Under normal operating conditions, a slight temperature rise is perfectly acceptable. However, overheating is a problem. Therefore, all users must pay extra attention to the “body temperature” of their centrifuges. After all, taking adequate preventive measures is the best way to avoid accidents altogether.
  When a centrifuge is first started, if you observe a peak that settles rapidly—reaching the bottom of the analysis cell within just a few minutes—this is usually due to partial polymerization of the sample, resulting in a highly sedimentable macromolecule. For example, protein samples may partially denature and precipitate when exposed to certain denaturing agents. After the centrifuge reaches its maximum speed, the centrifugation profile typically shows a symmetrical peak shape, which generally indicates that the sample has been uniformly distributed during centrifugation. However, to confirm the true homogeneity of the sample, additional methods such as electrophoresis or chromatography should be employed for further analysis. Occasionally, certain mixed samples may also produce a symmetrical peak. The peak shape usually broadens over time, a phenomenon caused by sample diffusion. However, if the peak broadening occurs very rapidly, the sample might be polydisperse. If the centrifugation profile reveals multiple peaks, it suggests that the sample contains several components; each peak corresponds to the sedimentation interface of a particular component, allowing us to determine the sedimentation coefficient of each individual component. Furthermore, by measuring the area under each peak, we can quantify the concentration of each component.

                                                        

                                                                      Centrifuge image       
  After each centrifuge run, be sure to intensify the water rinsing of the centrifuge drum. Based on our experience, if the drum is not thoroughly rinsed, sludge will adhere to the drum surface during the centrifuge’s downtime. As a result, when the centrifuge is restarted, the drum’s uneven stress distribution will disrupt its dynamic balance, causing severe vibrations. Whenever you finish cleaning the supernatant return pipe and re-install the liquid-level baffles, pay close attention to ensuring that all baffle plates are at the same height. Moreover, the tolerance for the baffle plate height must be within ±0.25 mm. Otherwise, the centrifuge may experience uneven stress distribution, leading to intense vibrations. In fact... Centrifuge It’s perfectly normal for centrifuges to generate heat during operation, because the machine consumes electrical energy when it’s running. As this electrical energy is converted into mechanical energy to drive the rotor of the centrifuge, some energy loss is inevitable in the conversion process. A portion of this energy is transformed into heat and dissipated outward, causing the centrifuge components to warm up. However, if the centrifuge components become excessively hot, it indicates that too much electrical energy has been converted into heat and lost. Based on its experience, Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. has identified three primary reasons for this phenomenon:
  The centrifuge’s power is too high, yet the actual power required is only this much—any excess power is lost and converted into electrical energy.
  Second, when the centrifuge operates under overload conditions, the current increases, and the rated power exceeds the actual power. The excess power is converted into heat and dissipated, causing the centrifuge components to overheat.
  3. Regarding issues with the centrifuge’s settings or start-up mechanism: When the centrifuge is started, its energy conversion efficiency is low. If the centrifuge is set to start too quickly or if there’s a problem with the start-up mechanism, it can lead to excessive power consumption and overheating even though the energy conversion efficiency remains low. Overheating of the centrifuge components can significantly shorten their service life. Therefore, it’s crucial to promptly identify and address the root cause of the centrifuge malfunction. Alternatively, you can contact the centrifuge manufacturer for technical support in troubleshooting the issue.
  Accidents are typically caused by improper operation of the centrifuge—for example, if the rotor is not properly seated on the spindle, the rotor lid is not securely closed, or the basket for swinging out the rotor is not positioned correctly. Such accidents are accompanied by a loud bang, and a centrifuge weighing 300 to 400 kg will suddenly spin at an angle exceeding 270 degrees. Upon opening the lid, you’ll find the rotor lying inside the chamber; when the rotor is removed, you’ll notice that its outer surface has been severely scratched and discolored. Additionally, the inner walls of the centrifuge chamber will also be damaged. Centrifuge Even refrigerant leaks can occur. Sometimes the rotor and rotor cover become separated, causing liquid from the test tube to spill into the chamber; in other cases, the spindle may break or bend severely.