How does a centrifuge detect the new African swine fever? Lu Xiangyi has the answer for you!
Release time:
2019-07-24
Overview:
As the saying goes, “A stable supply of pork ensures national stability.” The hog industry is a key sector that directly affects both the national economy and people’s livelihoods. After a year of concerted efforts, the momentum of the African swine fever epidemic in China has generally slowed down, and pig farmers’ confidence is steadily increasing. Moving forward, our primary focus will be on controlling and preventing African swine fever and restoring hog production. In the process of controlling and preventing African swine fever and conducting laboratory testing for the disease, Centrifuge Testing instruments and equipment will receive close attention.
During the use of the African swine fever centrifuge, proper operation is crucial. To address this, Shanghai Luxiangyi provided detailed explanations on the operational procedures for the new African swine fever assay, including pre-test preparations, self-provided experimental equipment required for the assay, sample handling and requirements for the new African swine fever analyzer, and the step-by-step operating procedures for the new African swine fever analyzer.
The Shanghai Luxiangyi TGL-16M African Swine Fever Centrifuge comes standard with a 1.5/2.2 ml × 24 rotor.
Preparation work before testing
Please take the reagent kit for the new African swine fever test out of the refrigerator 20 minutes in advance to allow it to equilibrate to room temperature.
The concentrated detergent solution taken from the refrigerator may exhibit crystallization, which is a normal phenomenon. Allow it to reach room temperature, gently shake to ensure even distribution, and wait until the crystals have completely dissolved before preparing the working detergent solution. You can dilute 20 ml of the concentrated detergent solution with distilled water or deionized water to prepare 400 ml of working-concentration detergent solution. Any unused portion should be returned to storage at 4°C.
3. To prepare a 20× washing buffer dilution: Dilute distilled water at a ratio of 1:20—that is, add 19 parts of distilled water to 1 part of 20× washing buffer.
Experimental equipment to be brought by participants.
1. New African Swine Fever Detector (450nm)
1. High-precision pipettes and tips: 0.5–10 µL, 2–20 µL, 20–200 µL, 200–1000 µL
3. Prepare a 37℃ incubator or a water bath.
4. Distilled water or deionized water
Sample Processing and Requirements for the New African Swine Fever Detection Device
Serum: Allow blood to clot naturally at room temperature for 10–20 minutes, then centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant; if any precipitate forms during storage, re-centrifuge the sample.
Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the specimen requirements. After mixing for 10–20 minutes, centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant; if any precipitate forms during storage, re-centrifuge the sample.
Urine for the new African swine fever detection device: Collect using a sterile tube and centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant; if any precipitate forms during storage, re-centrifuge. The same procedure applies to pleural and peritoneal fluids as well as cerebrospinal fluid.
Cell culture supernatant: When detecting secreted components, collect the supernatant using sterile tubes. Centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant. To detect intracellular components, dilute the cell suspension with PBS (pH 7.2–7.4) to achieve a cell concentration of about 1 million cells/ml. Perform repeated freeze-thaw cycles to lyse the cells and release their intracellular contents. Centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant. If any precipitate forms during storage, re-centrifuge the sample.
Tissue specimens for the new African swine fever detection device: After cutting the specimens, weigh them accurately. Add a specific volume of PBS at pH 7.4, then rapidly freeze them in liquid nitrogen for storage. Once thawed, maintain the specimens at a temperature of 2–8°C. Add an appropriate amount of PBS (pH 7.4), and thoroughly homogenize the specimens either manually or using a homogenizer. Centrifuge for approximately 20 minutes at 2,000–3,000 rpm. Carefully collect the supernatant. After aliquoting, set aside one portion for immediate testing, while freezing the remainder for future use.
After specimen collection, proceed with extraction as soon as possible. Extraction should be performed according to relevant literature, and experiments should be carried out promptly following extraction. If immediate experimentation is not feasible, the specimens can be stored at -20℃; however, repeated freeze-thaw cycles should be avoided.
7. Samples containing NaN3 cannot be tested, as NaN3 inhibits the activity of horseradish peroxidase (HRP).
Operating Procedures for the New African Swine Fever Detection Device
Take the required strips from the aluminum foil pouch after equilibrating at room temperature for 20 minutes; seal the remaining strips in a self-sealing bag and store them at 4℃.
Set up negative and positive control wells as well as sample wells. Add 50 μL of negative control to the negative control wells and 50 μL of positive control to the positive control wells.
Add 10 μL of the sample to be tested and 40 μL of the sample diluent to the well for the sample to be tested.
Subsequently, 100 μL of HRP-conjugated detection antigen, prepared using the new African swine fever test kit, was added to each of the negative control wells, positive control wells, and sample wells. The reaction wells were then sealed with sealing films and incubated at 37℃ in a water bath or a constant-temperature incubator for 60 minutes.
Discard the liquid, blot dry with absorbent paper, and then add fresh ASFV detection reagent wash solution to each well. Allow it to stand for 1 minute, then discard the wash solution and blot dry with absorbent paper. Repeat this washing procedure five times (a plate washer can also be used for this step).
Add 50 μL of substrate A and 50 μL of substrate B to each well, then incubate in a 37℃ water bath protected from light for 15 minutes.
Add 50 μL of stop solution to each well, and within 15 minutes, measure the OD value of each well at a wavelength of 450 nm using the new African swine fever detection instrument.
As a Chinese centrifuge manufacturer certified by the FDA in the United States, Shanghai Luxiangyi has now obtained ISO 9001:2015 quality system certification, ISO 13485:2003 quality system certification, and CE certification. The company has established a comprehensive system covering the entire lifecycle—from equipment manufacturing and sales to after-sales service. Its centrifuge products are exported to more than 30 countries, including the United States, Germany, the United Kingdom, Canada, and Thailand. “Continuous innovation and a forward-looking approach” are the goals that Luxiangyi strives to achieve. The company will do its utmost to provide users with high-quality products and services and is eager to establish extensive technical cooperation partnerships with both domestic and international enterprises!