A method for separating plant cell membranes using a high-speed centrifuge
Release time:
2015-05-13
Overview:
Here, you’d better get a high-speed centrifuge. I recommend the H2050 benchtop high-speed large-capacity centrifuge. If the centrifugal force isn’t strong enough, you might not be able to achieve separation. And if the raw material volume is very large, some of it might precipitate out.
For experiments in the chemistry lab, we’re using the Luxiangyi H2050 benchtop high-speed, large-capacity centrifuge. I’m providing you with a protocol that requires relatively little reagent. You can review it in light of your own specific circumstances.
Moreover, the plasma membranes obtained by this method are mostly microvesicles.
Using this method, we have successfully isolated the plasma membranes from Arabidopsis thaliana, maize coleoptiles, and tobacco suspension cells.
1. If the tissue is broken down, you can use a mortar and pestle. If there’s a large amount of coarse fiber present, you can also filter it through gauze.
Lysis buffer formulation: 0.55 M sucrose; 0.76 M Tris; 0.02 M EDTA; 0.03 M ascorbic acid. Adjust the pH to 7.8 using HCl.
Raw material/crackling liquid 1:2
2. The grinding solution is subjected to low-speed centrifugation in three steps to separate out unwanted tissue debris or cellular organelles. 100G for 10 minutes; 3,000G for 5 minutes; 17,000G for 15 minutes. (If the speed is insufficient, extend the duration appropriately; otherwise, a large number of organelles such as mitochondria will remain suspended in the supernatant.)
3. The suspension obtained in the previous step is a suspension containing total membranes. Generally speaking, the next step should involve high-speed centrifugation at a centrifugal force of 20,000 G or higher to precipitate all the membranes and further purify them. (Here, it’s best to find a high-speed centrifuge; I recommend the H2050 benchtop high-speed large-capacity centrifuge. If the centrifugal force isn’t sufficient, the membranes may not separate properly. If the starting material is abundant, some precipitates might form as well. You could also try adjusting the sucrose concentration in the lysis buffer—technically, changing the density will alter the sedimentation coefficient. However, this would require extensive computational work to ensure that membrane purity is not compromised.) Two methods are commonly used for purification: PEG/Dextran and sucrose gradient. The sucrose gradient method is older and its effectiveness isn't as good, but sucrose is inexpensive and easy to obtain. We use a 6.3% PEG/Dextran solution.
Moreover, the plasma membranes obtained by this method are mostly microvesicles.
Using this method, we have successfully isolated the plasma membranes from Arabidopsis thaliana, maize coleoptiles, and tobacco suspension cells.
1. If the tissue is broken down, you can use a mortar and pestle. If there’s a large amount of coarse fiber present, you can also filter it through gauze.
Lysis buffer formulation: 0.55 M sucrose; 0.76 M Tris; 0.02 M EDTA; 0.03 M ascorbic acid. Adjust the pH to 7.8 using HCl.
Raw material/crackling liquid 1:2
2. The grinding solution is subjected to low-speed centrifugation in three steps to separate out unwanted tissue debris or cellular organelles. 100G for 10 minutes; 3,000G for 5 minutes; 17,000G for 15 minutes. (If the speed is insufficient, extend the duration appropriately; otherwise, a large number of organelles such as mitochondria will remain suspended in the supernatant.)
3. The suspension obtained in the previous step is a suspension containing total membranes. Generally speaking, the next step should involve high-speed centrifugation at a centrifugal force of 20,000 G or higher to precipitate all the membranes and further purify them. (Here, it’s best to find a high-speed centrifuge; I recommend the H2050 benchtop high-speed large-capacity centrifuge. If the centrifugal force isn’t sufficient, the membranes may not separate properly. If the starting material is abundant, some precipitates might form as well. You could also try adjusting the sucrose concentration in the lysis buffer—technically, changing the density will alter the sedimentation coefficient. However, this would require extensive computational work to ensure that membrane purity is not compromised.) Two methods are commonly used for purification: PEG/Dextran and sucrose gradient. The sucrose gradient method is older and its effectiveness isn't as good, but sucrose is inexpensive and easy to obtain. We use a 6.3% PEG/Dextran solution.