Using crossmatching as an example, let’s explore the importance of centrifuges in medical laboratories.

Release time:

2021-12-13


Overview:

Centrifuges—whether used in medical settings or laboratories—are fairly common pieces of equipment. Take, for example, the process of crossmatching blood. Although it’s a simple procedure, it simply couldn’t be completed without a centrifuge.

   Centrifuge Whether in medical settings or laboratories, these are relatively common pieces of equipment.

  Take, for example, the matter of crossmatching blood. Although it’s simple, it can’t be done without a centrifuge.

  Crossmatching is an important basis for determining whether a blood transfusion can be safely administered. If neither side shows agglutination, the blood can be transfused. In this test, the donor’s red blood cells and serum are mixed separately with the recipient’s serum and red blood cells, and the presence or absence of an agglutination reaction is observed. This procedure is known as the crossmatch test. The crossmatch test necessarily requires the use of a centrifuge.

  Crossmatching should not be limited to saline-mediated crossmatching only. In laboratories with poor conditions, colloidal medium crossmatching should also be performed to minimize the risks posed by incomplete antibodies and reduce adverse reactions caused by blood transfusions.

  There are several methods for crossmatching, including the saline method, the gel-based crossmatching method, the antiglobulin method, and the polybrene method.

  The Microtubes Gel Test (MGT) is a new method that entered domestic laboratories in the 1990s and has since been used for crossmatching. In some advanced countries, it has become a standard serological technique for red blood cell typing. Moreover, the use of polybrene for the detection and identification of incomplete antibodies as well as for crossmatching and other serological tests has also been rapidly adopted and widely implemented domestically. This method is simple, time-efficient, and yields clear results.

  Economical and practical: One centrifuge equipped with three types of rotors is equivalent to three separate instruments. The three rotor options available are: a fixed-angle rotor; a horizontal rotor specifically designed for red blood cell washing; and a horizontal rotor for microcolumn gel assays. Rotor changes are simple and quick.

  Easy to operate: It comes with 11 built-in working programs and allows for the creation of up to 30 custom programs. Standard programs have been specifically designed for various serological blood typing experiments. Additionally, users can set up tailored programs as needed, ensuring that both clinical testing and research are standardized and normalized.

  Precise centrifugal force: quick start, speed measurement timing, automatic braking—resulting in more accurate centrifugal force.

  Wide applicability: Suitable for routine serological blood typing; red blood cell washing (washing 12 tubes is as simple as washing a single tube); microcolumn gel immunoassays, and more. The six-tube system simplifies the cumbersome procedures of traditional tube-based assays, reduces centrifugation time, and makes result interpretation easier.

  Note: Special-purpose rotors can be custom-made upon customer request.

  Crossmatching Procedure:

  1. Prepare blood samples from both the recipient and the donor.

  2. Prepare separately a 2.5% red blood cell saline suspension using physiological saline for the recipient and a 2.5% red blood cell saline suspension using the donor’s blood.

  3. Add 0.5 ml of the recipient’s serum to the main side, and 0.5 ml of saline suspension of the donor’s red blood cells.

  4. Add 0.5 ml of the donor’s serum to the secondary side and 0.5 ml of the recipient’s red blood cell saline suspension.

  5. After thorough mixing, depending on the crossmatching method used—for example, enzyme-based crossmatching—incubate in a 37°C water bath for 1 hour and then directly observe whether agglutination or hemolysis has occurred. If a saline medium or other similar method is employed, centrifuge at 1000 rpm for 1 minute; alternatively, use a specific centrifugation speed and duration as recommended by the polybrene reagent.