Essential tips for operating a high-speed refrigerated centrifuge!

Release time:

2018-10-17


Overview:

The operation of a high-speed refrigerated centrifuge is not complicated—once it’s properly adjusted, the operation will go smoothly!

   High-speed refrigerated centrifuge The operation process isn't complicated—once you’ve got the debugging right, everything will run smoothly!
  Shanghai Luxiangyi Centrifuge Instrument Co., Ltd., with years of experience in the production and sales of high-speed refrigerated centrifuges, has accumulated valuable insights from the commissioning and use of various products. Therefore, the following is a technical sharing provided by our technical specialist:
  What other highlights does a high-speed refrigerated centrifuge offer while extracting the desired components from liquid mixtures?
  I. Intelligent Software Workflow: Selection of Rotors for High-Speed Refrigerated Centrifuges
  During prototype debugging, control subroutines for seven rotor models have been identified, suitable for rotors operating at speeds ranging from several thousand to thirty thousand revolutions per minute. In practical application, users only need to enter the rotor model they are using via the keyboard.
  In the event of control failures or mechanical system malfunctions, the system should be able to detect them promptly and trigger an alarm, shutting down all controlled devices to minimize system damage. At the same time, if faults that do not affect production—such as damaged keys or abnormal displays—are detected, the system should issue an alarm to alert the operator without halting production.
  Problems Encountered During Debugging and Their Solutions
  (1) Some production workshops are located next to power-frequency quenching furnaces or electric welding workshops, where industrial interference is relatively severe and significantly affects the normal operation of the system, often causing the program to “run wild.” To address this issue, the instrument design has incorporated various anti-interference measures, including:
  a. Software anti-interference measures;
  b. In addition to implementing white reset measures, the hardware has also been further enhanced with shielding and isolation measures.
  c. Use an independent power supply (with phase separation from the interference source) or install a UPS power supply;
  d. An IRC absorption circuit was added to the relay coil. With these measures in place, the system has been functioning normally ever since and has not experienced any further crashes.
  (2) The sampled signal was unstable, which compromised the reliability of the control system. Due to severe interference, the signal’s stability was affected, leading to spurious phenomena in the sampled signal and triggering false operations. Based on our analysis of the phenomena observed on-site, we ultimately addressed this issue by adding a hardware filtering circuit upstream.
  Operating Procedures for High-Speed Refrigerated Centrifuges:
  The densities of the centrifuged samples must be identical, and they should be kept 3 mm from the tube opening.
  Place the centrifuge tubes—identical in density, properly balanced, and with dry tube walls—in a symmetrical arrangement inside the rotor basket. Tighten the corresponding tube caps and hang the assembled rotor basket onto the designated rotor basket holder. Even empty rotor baskets must be hung properly. This ensures that the rotor experiences uniform horizontal forces during operation; otherwise, a severe laboratory accident involving shaft breakage could occur. —Shijiazhuang Huachen Letian Biological Laboratory Equipment Co., Ltd.
  Close the lid of the high-speed refrigerated centrifuge.
  Turn on the high-speed refrigerated centrifuge.
  Gently place the rotor, which is suspended from the hanging basket, straight down onto the spindle sleeve, ensuring that it is securely fastened.
  Tighten the head cover.
  Press down on the door cover at the designated location.
  High-speed refrigerated centrifuge centrifugation parameter settings: speed, time, rotor model, temperature, and lifting/raising speed frequency (the rotor identification function is now available for automatic rotor recognition).
  Confirm that the parameter settings are correct, then press the START button. The high-speed refrigerated centrifuge may be left only after it has reached the set speed and stabilized for 5 minutes. During the centrifugation process, monitor the instrument to ensure it is operating normally.
  After the centrifugation is complete (or when you press STOP to end the run), once the rotor has come to a stop, open the door cover, loosen the rotor cap, remove the rotor, and place it onto the dedicated rack. Then, remove the basket and take out the samples.
  Place the hanging basket open in the designated location. If there’s any leakage, remove the sealing ring, wash it thoroughly, and then place it upside down on a tablecloth.
  Turn off the instrument's power.
  Wipe clean the condensation inside the centrifuge chamber.
  The above are the key operational guidelines for high-speed refrigerated centrifuges. We hope they will be helpful to our users. If you have any questions, please call Shanghai Luxiangyi Centrifuge Instrument Co., Ltd., and we’ll be happy to engage in a thorough exchange with you!