The Shanghai Luxiangyi Centrifuge Speeds Up Blood Testing.
Release time:
2018-11-27
Overview:
Abstract: An improvement in testing efficiency can involve enhancing a specific function of a device—for example, in hospital blood tests, after each sample is collected and analyzed, the cap must be removed. This process is time-consuming, and some physicians with less strength may even find it difficult to remove the caps smoothly!
Shanghai Luxiangyi Centrifuge Instrument Co., Ltd. has addressed this issue by— Centrifuge We have designed and developed an advanced, automated cap-removal centrifuge—the model TD4T—which delivers remarkable performance and completely resolves the longstanding issue of difficulty in removing caps from vacuum blood collection tubes in hospitals at all levels. It is the ideal instrument for blood testing centrifugation in hospitals of all types and at all levels.
Why is that so? Because the TD4T automatic cap-removing centrifuge addresses a common issue in hospitals at all levels: when collecting blood samples, vacuum blood collection tubes are widely used. After centrifuging the blood samples, staff manually remove the tube caps—a process that is inefficient. Moreover, the vibrations generated during cap removal can cause the blood to remix, increasing the risk of bacterial contamination.
At the same time, the TD4T automatic decapping centrifuge also features the following 8 characteristics:
1. The vacuum blood collection tube automatically removes the cap, with a cap removal success rate exceeding 90%.
2. The TD5T and D5T are suitable for vacuum blood collection tubes with lengths of 106 mm, 101 mm, and 81 mm.
3. TD4T is suitable for vacuum blood collection tubes with lengths of 106 mm and 81 mm.
4. Large-screen LCD or digital display, user-friendly interface, simple and convenient operation.
5. Real-time conversion and setting between RPM and RCF for convenient and quick operation.
6. Electronic door lock—safe and reliable, featuring an integral sealing ring made of food-grade silicone rubber.
7. It features a special shock-absorbing structure that delivers excellent shock absorption and includes an automatic balancing function.
8. Equipped with multiple protection functions, including unbalance protection, overspeed protection, and door cover protection.
Next, let me explain how to proceed:
Step 1: After centrifugation is complete, simply pick up the cap-removal basket. The blood collection tubes and tube caps will automatically separate, as shown in the schematic diagram below.

Remove the cap and place the basket into the vacuum blood collection tube.

2. Under the action of centrifugal force, the vacuum blood collection tube sinks, and the tube cap separates.

3. Remove the upper-level cap-hanging basket adapter.

4. Remove the test tube cap—separation is complete.

Finally, let me introduce this centrifuge accessory:
The LTK72 rotor, with a capacity of 7 ml × 18 × 4, can be equipped with the above-mentioned adapter.