High-speed refrigerated centrifuge prevents high- and low-pressure surge.

Release time:

2015-10-26


Overview:

High-speed refrigerated centrifuge
  Abstract: High-speed refrigerated centrifuge What most significantly affects experimental accuracy? After years of research, it has been found that surge is the primary factor—a truly lethal threat. Freezing centrifuges and high-speed centrifuges are particularly prone to this phenomenon. Moreover, in severe cases, surge can damage components such as the centrifuge rotor. In other words, any external factor that causes the operating point of a high-speed freezing centrifuge to shift into the surge region relative to the pipeline network can trigger surge.
  During experiments, a malfunction of the high-speed refrigerated centrifuge can lead to experimental failure or even render the experiment unfeasible. Faced with such centrifuge malfunctions, many centrifuge operators feel helpless. Although they can contact the centrifuge supplier for assistance, the entire process—from initial communication to after-sales repair—still takes at least two to three days at the very least. Thus, it ends up being quite time-consuming. In fact, many straightforward issues with centrifuges can be resolved by the operators themselves, which would save a considerable amount of time.
  From the perspective of the performance curve of high-speed refrigeration centrifuges, when surge occurs in a refrigeration centrifuge, its operating point invariably enters the surge region. Therefore, severe surge in refrigeration centrifuges is closely related to the characteristics of the connected pipeline network. In the theoretical operation of high-speed refrigeration centrifuges, the following factors can trigger surge: switching defects in the air separation system; failure to promptly open relief valves or anti-surge valves during electrical faults or interlock shutdowns; and failure to promptly open valves leading to the main heat exchanger or molecular sieve adsorber, resulting in excessively high discharge pressure in the high-speed refrigeration centrifuge. This causes the pipeline network’s characteristic curve to become sharply steeper, rapidly shifting the operating point away from the centrifuge’s stable working range and into the surge region, thereby triggering surge. High-speed refrigerated centrifuge During the boosting process initiated by operator control, there is a lack of coordination in the control actions, the boosting rate is too fast, and the inlet guide vane opening is small. The power grid quality is poor—either the grid frequency drops or the voltage falls below the acceptable level—causing the motor to stall and driving the centrifuge flow rate into the surge region. Additionally, the flow passages of the refrigeration centrifuge are blocked. This is due to leakage from the cooler or accumulation of dust and scale, which has roughened the flow passages at each stage and reduced the cross-sectional area of certain sections.
  High-speed refrigerated centrifuges are widely used in the pharmaceutical industry and remain the primary equipment for separation in current active pharmaceutical ingredient (API) production processes. Due to the varying application scenarios, processes, and physical and chemical properties of the media employed by pharmaceutical manufacturers, centrifuges are subject to different requirements—for example, corrosion resistance, explosion-proof specifications, medium temperature, and workshop cleanliness levels.
  The spindle control system governs the rotation of the centrifuge’s entire arm, and its precision and stability are critical to the performance of the entire system. The spindle control system manages the centrifuge’s rotational speed, rotation mode, and displays operational status. The high-speed refrigerated centrifuge is responsible for transmitting certain operational states to a remote central management unit and can receive control commands from the central management unit. It uses a WDM driver to control the operation of the spindle.
  The frequency converter drives the rotor of a high-speed refrigerated centrifuge, ensuring smooth startup and adjustable separation factors. It completely overcomes the drawbacks of traditional DC brush-type centrifuges—such as high noise levels, frequent failures, short service life, and unstable rotational speed—and represents an upgraded, next-generation product for gravity sedimentation separation equipment. The AC frequency-converter centrifuge features distinct characteristics and originality in several key areas, including its vibration-damping system and frequency-converter motor.
   High-speed refrigerated centrifuge The intake resistance is high, for example, due to a clogged filter or an obstruction at the impeller inlet. Under normal circumstances, during installation and commissioning, surge testing is conducted, and the pressure and current are adjusted via PI control to effectively prevent both high- and low-pressure surges.