Although the pocket-sized centrifuge is small, you can’t afford to overlook even the smallest detail.
Release time:
2023-02-01
Overview:
A handheld centrifuge is another name for a mini centrifuge.
The handheld centrifuge boasts the advantage of its compact size. It’s a palm-sized, personal centrifuge that comes with a variety of adapters for interchangeable rotors. With reliable performance and simple, convenient operation, it’s an ideal device for rapidly spinning microcentrifuge tubes and PCR tubes.
In fact, the handheld centrifuge is primarily used for separating tiny samples. Don't be fooled by its small size—its functionality is in no way inferior to that of its larger counterparts!
Take the Luxiangyi TG10K centrifuge as an example: its external dimensions are only 189mm x 161mm x 122mm. Despite its compact size, it features quiet operation technology and a maximum speed of 10,000 rpm, with a relative centrifugal force of 5,000×g. The sample processing capacity is 1.5 ml / 0.5 ml / 0.2 ml × 6.
It can also be equipped with rotors and tube adapters of various specifications to meet the needs of different experiments. At its maximum speed, the handheld centrifuge applies centrifugal force rapidly and uniformly to both the caps and walls of microcentrifuge tubes, making it particularly well-suited for handling PCR tubes and microfiltration applications.
Although small in size, you still need to pay close attention to the same precautions when using it. In particular, never open the lid while the machine is running—most modern handheld centrifuges are now equipped with a safety feature that automatically stops the device if the lid is opened—to prevent high-speed components from flying out and causing injury. Below, we’ve compiled the key precautions for using this instrument:
1. When using, place the handheld centrifuge on a level surface. The voltage of the external power supply must match that of the instrument, and a good grounding wire is required. Do not pile up clutter around the instrument; leave at least 10 cm of space to facilitate heat dissipation.
2. Before powering on, first check whether the rotor of the handheld centrifuge is securely installed and whether there are any foreign objects inside the machine chamber. Also, verify that the base bolts, rotor drum, V-belt, and braking system are all intact and in good working order.
3. Samples should be pre-equilibrated, and when using centrifuge tubes, both the centrifuge tubes and the samples must be equilibrated simultaneously. It is crucial not only to ensure that the samples have equal weight but also to take into account the balance of density and volume. This is because the torque generated during centrifugation depends not only on the type of sample but also on the radius at which the sample is located. If the centrifuge is started with an unbalanced load, it could damage the equipment or even injure the operator.
4. When centrifuging volatile or corrosive liquids, use centrifuge tubes with lids to prevent liquid leakage that could damage the instrument or pose a safety hazard.
5. Avoid using non-standard test tubes to insert into the centrifuge rotor.
6. Do not operate the centrifuge when its top cover is open. After centrifugation is complete, wait until the instrument has completely stopped rotating before opening the top cover. If any abnormality occurs during operation of the centrifuge, immediately turn off the power and notify technical personnel for repair.
7. The typical duration of a single use of the handheld centrifuge is 1 to 2 minutes. Experimental personnel must keep a close watch on the device at all times and must not leave it unattended to prevent accidents.
8. After using the handheld centrifuge, clean it promptly. When wiping the chamber, use gentle motions to avoid damaging the temperature sensor.
9. The centrifuge should normally be stored in a dry, room-temperature environment, avoiding direct sunlight, drastic temperature fluctuations, and exposure to water or moisture.
After watching the explanation above, do you now have a new understanding of the handheld centrifuge?