A biosafety centrifuge is an essential piece of equipment in the laboratory.
Release time:
2020-08-21
Overview:
A biosafety centrifuge is... Laboratory centrifuge In a testing laboratory, the workload is substantial. Every day, the lab must handle a wide variety of clinical specimens—from patient blood and body fluids to secretions and excreta. Among these specimens, blood samples account for the largest volume. All blood samples must be centrifuged to separate the serum before analysis, and many other specimens also require centrifugation. As a result, the utilization rate of centrifuges is extremely high. During the centrifugation process, if test tube caps are not tightly sealed or are missing altogether, or if tubes are accidentally dropped or removed improperly, or if they are placed unevenly or break, specimen spillage can occur, contaminating the centrifuge. Moreover, as centrifuges operate at high speeds, they generate aerosols. Since these specimens come from patients with various diseases, they may contain pathogenic microorganisms and biomolecules that pose serious risks to both the environment and human health. Dust or contaminants inside the centrifuge, when subjected to high-speed rotation, can also produce aerosols that cause significant damage to the human respiratory, digestive, and nervous systems. Therefore, disinfection of centrifuges and effective control of aerosol generation in testing laboratories are of paramount importance.
Simply place the rotor onto the centrifuge spindle, and when the centrifuge starts running, the rotor will automatically lock onto the spindle—no need to use rotor locking bolts at all. After the centrifugation is complete, the rotor will automatically release from the spindle, making it easy to remove.
Basic structure of a biosafety centrifuge:
Biosafety rotor
The Biosafe rotor effectively controls aerosols, ensuring that aerosols generated during high-speed operation—whether from pathogenic microbial samples or from dust and contaminants within the centrifuge—are safely contained and preventing any aerosol leakage from the rotor.
Ultra-convenient rotor loading and unloading method
Help take biosecurity prevention and control all the way to the end.
The single-knife locking mechanism allows you to quickly and easily install and remove the rotor cover within 2 seconds, making operation convenient and saving you time when handling samples in the safety cabinet.
Centrifuge separation technology greatly facilitates the frequent transfer of biosafety rotors between centrifuges and biosafety cabinets.
It is essential to use a biosafety rotor strictly: After centrifugation is complete, the entire rotor must be transferred into a biosafety cabinet before the rotor lid is opened. Otherwise, the intended protective effect against aerosols and hazardous substances will not be achieved.
The centrifuge should be in normal working condition and possess qualified mechanical performance to prevent injury accidents. Operate according to the manufacturer’s instructions, and standard operating procedures should be established. Place the centrifuge in an appropriate location and at a suitable height so that operators can easily see the centrifuge buckets and conveniently perform tasks such as replacing rotors, properly placing centrifuge tubes, and securely tightening rotor caps.
Centrifuge tubes and specimen containers used for centrifugation should be selected according to the manufacturer’s instructions. It is best to use plastic products, and prior to use, they should be carefully inspected for any signs of damage. It is important to ensure that the centrifuge tubes or containers being used can withstand the specified centrifugal force or speed to prevent them from rupturing. Centrifuge tubes and specimen containers used for centrifugation must always be tightly sealed; screw-top caps are preferred whenever possible. When handling infectious materials, the container lids must be opened inside a biosafety cabinet. When using rotors, it is crucial to verify that the rotor cap matches the rotor model.