Extraction and Analysis of Bacterial Fatty Acids
Release time:
2018-09-10
Overview:
Reagents: 0.3% formaldehyde, 6 mol/L HCl-CH3OH solution, chloroform. Method: Analysis and determination by GC-MS coupled technique, with the procedure as follows:
(1) Culturing and Collecting the Microbial Cells
The experimental strains in Group I were cultured in YPD liquid medium supplemented with a certain amount of cryoprotectant. After inoculation, the cultures were placed in a shaker at 30°C and 150 rpm for 24 hours. The cells were shaken until they reached the mid-log phase of growth. An appropriate amount of cell suspension was then transferred to a freezer at -30°C and frozen for 7 days. Upon retrieval, the samples were thawed at 30°C for 5–10 minutes, followed by inactivation using 0.3% formaldehyde. The cells were centrifuged at 4000 rpm for 5 minutes, after which the supernatant was discarded. The cells were washed with distilled water, centrifuged again to collect the cell pellet, and then frozen at -18°C. Finally, the cells were freeze-dried under vacuum to obtain lyophilized cells, which were stored for further use.
The blank sample was inactivated with 0.3% formaldehyde, then centrifuged at 4,000 r/min for 5 min. The supernatant was discarded, and the cells were washed with distilled water. The cells were collected by centrifugation, frozen at -18°C for 24 hours, and subsequently freeze-dried to obtain lyophilized cells for later use.
The experimental strains in Group II were used to prepare frozen dough for bread. Antifreeze protectants were added, and the dough was frozen at -20°C for 30 days before being removed and thawed. Twenty grams of the thawed dough were dispersed in 180 ml of sterile water, shaken vigorously for 30 minutes, allowed to stand for 15 minutes, then centrifuged, and the supernatant was collected. The supernatant was inactivated with 0.3% formaldehyde, followed by centrifugation at 4,000 r/min for 15 minutes. The supernatant was discarded, the cells were washed with distilled water, and the cell pellet was collected by centrifugation. The cells were then frozen at -18°C and subjected to freeze-drying under vacuum to obtain stem cells for future use. For the blank control sample, no antifreeze protectant was added; all other processing steps were identical.
(2) Methylation and Extraction of Fatty Acids
Take 50 mg of freeze-dried cells and add them to 2 ml of a 6 mol/L HCl-CH3OH solution. Subject the mixture to hydrolysis with hydrochloric acid at 100°C for 3 hours. The resulting solution will turn brownish (or dark brown). Remove the mixture and allow it to cool down to room temperature. Then, add 1.5 ml of n-hexane and shake vigorously. Centrifuge at 4000 r/min for 10 minutes, carefully collect the supernatant, and repeat the extraction once more by adding another 1.5 ml of n-hexane. Combine the two supernatants. Next, add 3 ml of distilled water to the combined supernatant and centrifuge again at 4000 r/min for 10 minutes. Collect the supernatant into a centrifuge tube. Dry the supernatant under a stream of dry nitrogen, then add 10 μl of chloroform to prepare the fatty acid methyl ester derivative.
(3) Thin-layer chromatography
Take the fatty acid esterification solution using a glass capillary and spot it onto a silica gel G-TLC thin-layer plate. Use a developing solvent system consisting of n-hexane plus anhydrous diethyl ether (1:1). As soon as the developing solvent reaches the top edge of the silica gel plate, immediately remove the plate and allow it to air-dry. Examine the purity and relative concentration of the prepared fatty acids under a UV254 lamp. Carefully mark the fatty acid methyl ester band, gently scrape it off, and extract it twice with diethyl ether. After drying under nitrogen, add 0.5 ml of anhydrous methanol, shake vigorously to dissolve the sample, and then proceed with GC-MS analysis.
(4) GC-MS Operating Conditions
Programmed temperature increase: Initial temperature 130°C, held for 1 min; final temperature 280°C, held for min; heating rate 7.6°C/min. Detector temperature 250°C; carrier gas (He) flow rate 30 ml/min; split ratio 50:1; He flow rate 49.9 ml/min; injection volume 1 μl. (2) MS conditions: 280°C; mass scan range 35–500.