Method for Determining Milk Fat Percentage Using a Cream Separator

Release time:

2014-04-01


Overview:

Then, place the test bottles into the cream separator and rotate them at 100 revolutions per minute for 5 minutes. (In winter, if the contents of the test bottles have cooled down or cannot be immediately separated, they must be placed in a water bath before separation.)

(1) Babcock Method: First, heat the milk sample to 10–20°C. Use a milk sampling tube to thoroughly mix the milk sample. Then, draw 17.6 ml of milk from the middle portion of the sample and transfer it into the test bottle. When transferring the milk, tilt the test bottle slightly, ensuring that the sampling tube does not fully enter the bottle’s opening. Using a pipette, carefully measure 17.5 ml of sulfuric acid with a density of 1.82–1.83 (at 20°C), and slowly add it along the inner wall of the test bottle. Gently rotate the test bottle with your finger to allow the sulfuric acid to rinse any milk adhering to the bottle’s mouth into the bottle. The sulfuric acid must be added in several portions; after each addition of a small amount of acid, gently shake the test bottle to ensure that any clotted curd is completely dissolved, continuing until all the sulfuric acid has been added. Once the acid addition is complete, hold the neck of the test bottle with your fingers and perform a long, circular motion to thoroughly mix the sulfuric acid with the milk and ensure full reaction. When the mixture turns coffee-colored or cherry red, indicating that all the protein has been dissolved, you can stop rotating the bottle. Next, place the test bottle into the cream separator. Rotate the centrifuge at 100 revolutions per minute for 5 minutes. (In winter, if the contents of the test bottle have cooled down or cannot be immediately separated, place the bottle in a water bath beforehand to maintain the water temperature at 60–70℃ for 15–20 minutes.) After separation is complete, remove the test bottle and slowly add distilled water at 60–70℃ along the inner wall of the bottle neck until it reaches the base of the neck. Then, place the bottle back into the cream separator and rotate it for another 2 minutes. Once separation is finished, remove the test bottle again and add more distilled water at 60–70℃, allowing the fat column to rise to the 5th or 6th mark on the bottle neck. Place the bottle back into the cream separator and rotate it for an additional 1 minute. Finally, remove the test bottle and immerse it in a water bath maintained at 60–70℃, ensuring that the water level is flush with the top of the fat column. After about 1–2 minutes, take the bottle out of the water bath. Using a pair of calipers, place one foot on the horizontal plane at the base of the fat layer and the other foot on the top of the fat column. Then, move the second foot from its current position to the “0” mark on the scale. The percentage of fat content can now be read directly from the point where the second foot has been moved.

(2) Gerber Method: The sample milk is processed in the same way as the Pasteur method. Using a graduated cylinder, measure 10 ml of sulfuric acid with a density of 1.82 to 1.83 and add it into the Gerber test tube. After thoroughly mixing the sample milk with a milk suction tube, carefully pipette 1 ml of the sample milk and slowly inject it into the test tube. Next, using a fine pipette, draw 1 ml of isoamyl alcohol and add it into the test tube. Securely close the test tube with its stopper, then shake it vigorously up and down to ensure complete dissolution of the proteins. Place the test tube into a water bath maintained at 65–70°C and keep it there for 3–5 minutes. Then, place the test tube into the metal cylinder of the butterfat centrifuge (with the pointed end facing toward the center of the centrifuge), close the lid, and rotate at 100 revolutions per minute for 5 minutes. Once separation is complete, remove the test tube and immerse it in a water bath at 65–70°C for 3–5 minutes (during immersion, keep the coarse end facing downward). After removing the test tube from the water bath, read the fat percentage. To read the result, first rotate the rubber stopper so that the lower end of the fat column aligns with the “0” mark.