Once you understand these three questions, operating a centrifuge won't be difficult at all.

Release time:

2020-06-17


Overview:

Understanding these three issues will make operating a centrifuge a breeze. When using a centrifuge, don't be careless—while safety must always come first, you should also strive to ensure the accuracy of your results as much as possible. The following three issues are commonly encountered during use.

  In use Centrifuge During the process, you might encounter the issue of insufficient centrifugal speed. Some people might think of solving this by simply extending the centrifugation time. Here, the editor would like to tell you seriously: no!

  This approach is not advisable—it’s simply impossible. Don’t waste your time; if you’re going to replace the equipment anyway, just go ahead and do it.

  Someone might ask: What if we’re dealing with a small-scale scenario and have already calculated the required time using a formula?

  Let me give you an example:

  That kind of centrifuge, which is even bigger than a washing machine, requires extremely precise balancing before samples are loaded. The centrifuge tubes themselves are specially designed, and reportedly, they’re even evacuated to a vacuum before the centrifugation begins. Some centrifugation runs last for dozens of minutes—or even hours! So how can you extend the duration? In a nutshell: if the centrifugal force isn’t sufficient, no amount of time will make a difference.

  Another issue is that after using the centrifuge, the centrifuge tubes might get stuck and unable to be removed—this is a fairly common problem. If you encounter this situation, don't worry at first. Learn to rule out possibilities yourself—for example:

  Excluding the issue with the centrifuge rotor, the rotor is definitely fully symmetrical and compliant—so the problem doesn't lie there.

  Take a look at the solvent’s behavior—could it be that the solvent you’ve put into this tube, such as an organic solvent, has caused the centrifuge tube to swell and become stuck, preventing it from coming out?

  Let’s take another look to see if the balancing wasn’t done properly. If the balancing isn’t right, this tube will be just a tiny bit heavier, resulting in greater centrifugal force during the centrifugation process and causing it to fit more tightly than the others. (If both the tubes and the rotor are of standard specifications, this scenario is highly unlikely.) The most likely explanation is that there’s a quality issue with the centrifuge tubes themselves—specifically, uneven specifications or a slight oversized dimension.

  In short, if the centrifuge tubes are of good quality and all the same size, it’s possible that this particular tube has deformed during sterilization or use, causing it to fit more tightly.

415.png

  Let’s discuss another common question: Under what circumstances would you use a centrifuge? Couldn’t solid-liquid separation just be handled by filtration?

  To analyze this issue, let’s first gain a conceptual understanding:

  Centrifugation: The principle behind separation lies in centrifugal force, which is related to the mass of the analyte.

  Filtration: The separation principle is similar to size exclusion and is highly correlated with the volume of the analyte. Sometimes, filtration also requires the assistance of centrifugal force, especially in ultrafiltration.

  The purposes of the two methods also differ: filtration is used to remove large particles and obtain smaller ones, while centrifugation can separate small particles from large ones—leaving the small particles in the supernatant and causing the large particles to settle at the bottom, allowing you to collect the desired fraction.

  However, if you're measuring content uniformity, you'll need to use a centrifuge, because there's a strong possibility that the filter membrane may adsorb the active ingredient, which could lead to inaccurate measurement results. Filtration can be used to determine related substances; generally, the self-control method is more commonly employed. Even if the active ingredient is adsorbed by the filter membrane, this typically has little impact on the determination of related substances.

  In short, there’s no definitive answer to whether to use centrifugation or membrane filtration—everything depends on the properties of the drug itself, particularly the physicochemical characteristics of the active pharmaceutical ingredient, such as particle size, which is a crucial factor.

  When developing standard procedures, you must base them on your research data—rather than mechanically relying on phrases like “use filtration” or “determine content by centrifugation.”