How to choose a suitable centrifuge?

Release time:

2014-07-15


Overview:

The centrifuge is one of the most commonly used basic pieces of equipment in laboratories. When selecting a precision centrifuge, you should pay attention to the following five factors: 1) rotational speed, 2) temperature, 3) capacity, 4) rotor, and 5) control system.

The centrifuge is one of the most commonly used basic pieces of equipment in laboratories and is widely employed in hospital laboratories. It is an indispensable tool for tasks such as separating serum from blood, precipitating formed cells, concentrating bacteria, and performing PCR tests, among others.

There are numerous centrifuge manufacturers in China, many of which are small-scale operations with just a dozen or so employees. Yet these smaller companies are also producing centrifuges, and their product quality and after-sales service often fail to meet customer demands. Therefore, when purchasing a centrifuge, it’s still advisable to do some thorough research first. There are two effective ways to assess the true capabilities of centrifuge manufacturers: one is to examine customer feedback and word-of-mouth testimonials, and the other is to evaluate the manufacturer’s facility size, investment in equipment, and after-sales service offerings. Many promotional images online are fake and can be quite difficult to distinguish. As a recommendation, I suggest users try searching for the company name on Baidu Maps—for example, “Shanghai Luxiangyi Centrifuge.” On the left side, you’ll see the search results. Among those results, you’ll notice a label indicating “panoramic view with camera.” Clicking on that link will take you to an authentic 3D panoramic image. This street-view imagery is created by a third-party company affiliated with Baidu and carries considerable authenticity. If you’re still not entirely confident, why not pay a visit to the manufacturer’s facility yourself and take a closer look?


When selecting a standard centrifuge, you should primarily consider two factors—rotational speed and capacity—based on the volume of work involved.

The following provides detailed information on the issues that should be considered when selecting a precision centrifuge:

1. Rotational Speed: Centrifuges are classified according to their maximum rotational speed as follows: low-speed centrifuges—less than 10,000 rpm/min; high-speed centrifuges—10,000 to 30,000 rpm/min; and ultrahigh-speed centrifuges—over 30,000 rpm/min. Each centrifuge has a rated maximum rotational speed, which refers to the speed achieved under no-load conditions. However, the maximum rotational speed can vary depending on the type of rotor used and the mass of the sample being processed.

For example, if a centrifuge has a rated speed of 16,000 rpm/min, this means that under no-load conditions, the rotor spins 16,000 times per minute. However, once samples are loaded into the rotor, the actual rotational speed will certainly be lower than 16,000 rpm/min. Different rotors have different maximum speeds. A single centrifuge can be equipped with multiple rotors—for instance, the TG16-WS benchtop high-speed centrifuge, the TGL-16WS, and the TGL-20MS benchtop high-speed refrigerated centrifuge, among many other models—each of which can accommodate up to 16 different types of rotors, allowing for versatile multi-purpose use. Horizontal rotors can reach speeds of up to 5,000 rpm/min, while angle rotors can typically achieve speeds of around 25,000 rpm/min. For specific differences, it’s best to consult in detail with the product sales staff and the technical specialists at the manufacturer. Therefore, when selecting the appropriate speed, you must be careful: the maximum speed of the centrifuge you choose should exceed your target speed.

For example, if the target rotational speed is 16,000 rpm/min, the maximum rotational speed of the centrifuge you select must exceed 16,000 rpm/min. Generally speaking, the effectiveness of separation depends less on the rotational speed itself and more on the centrifugal force generated. Therefore, even if the rotational speed doesn't quite reach the required level, as long as the centrifugal force meets the specifications, the desired separation effect can still be achieved during the experiment.

Centrifugal force calculation formula: RCF = 11.2 × R × r/min / 1000², where R represents the centrifugal radius and r/min represents the rotational speed.

2 Temperature: Some samples, such as proteins and cells, can be damaged when exposed to high temperatures. In such cases, it’s essential to choose a refrigerated centrifuge, which comes with a specified temperature range. During high-speed operation, the heat generated by the centrifuge must be balanced by its cooling system to maintain a stable temperature. Typically, samples subjected to refrigerated centrifugation need to be kept within a temperature range of 3℃ to 8℃. The exact temperature achievable also depends on the rotor used. For example, if a centrifuge has a rated temperature range of -5℃ to +35℃, when equipped with a horizontal rotor, the temperature during rotation can reach around -4℃; however, if an angle rotor is used, the temperature might only drop to about 0℃. It’s important to consult in detail with the product sales representative and the technical staff at the manufacturer regarding these specifics.

3 capacity How many sample tubes need to be centrifuged each time? And how much capacity is required for each sample tube? These factors determine the total capacity of a centrifuge. Simply put, the total capacity of a centrifuge equals the capacity of each centrifuge tube multiplied by the number of tubes. The total capacity should be matched to the volume of work to be performed.

4. Rotors: Centrifuge rotors are mainly divided into two types: horizontal rotors and angle rotors. In a horizontal rotor, the rotor basket remains horizontal during operation, positioned at a right angle to the rotation axis; samples settle and concentrate at the bottom of the centrifuge tubes. In an angle rotor, the rotor container is fixed at a specific angle relative to the rotation axis; samples settle and concentrate both at the bottom of the centrifuge tubes and along the side walls near the bottom. If you want the separated samples to concentrate exclusively at the bottom of the centrifuge tubes, choose a horizontal rotor. If you want the samples to concentrate both at the bottom and along the side walls near the bottom, opt for an angle rotor. Additionally, certain special experiments or particular sample types may require specialized rotors—for example, large-capacity rotor baskets commonly used in blood banks, enzyme-linked immunosorbent assay (ELISA) plate rotors, slide rotors, PCR rotors, tube rack rotors, and capillary rotors. Each rotor has fixed specifications that are closely linked to the capacity of the centrifuge. For instance, a 36×5ml angle rotor not only determines the type of rotor but also dictates the maximum capacity of the centrifuge. Therefore, selecting the right rotor is extremely important.

5. Control Systems: High-end centrifuges are equipped with microcomputer control systems that not only ensure safe operation but also automatically perform various tasks. Nowadays, many centrifuges feature user-friendly control systems that offer a range of convenient features, such as rotor identification, safety lock functions, fault-alert indicators, and customizable acceleration and deceleration curves. In addition to these key features, it’s important to pay attention to certain details and essential accessories. The main component of a centrifuge is the motor, which can be either brushed or brushless. Brushed motors have largely been phased out, and today most centrifuges use brushless motors; some even come with built-in braking mechanisms. Refrigerated centrifuges also differ in their cooling technologies—currently, environmentally friendly refrigeration methods, such as fluorine-free cooling, are preferred. Beyond that, noise levels should be carefully considered; whenever possible, choose a centrifuge with lower noise output to maintain a comfortable laboratory environment. When it comes to accessories, caution is key. Some experiments require special centrifuge tubes—for instance, when handling toxic samples or samples needing ultra-high-speed centrifugation—such tubes must be paired with appropriate tube sleeves for enhanced safety. Additionally, there are specialized sample containers, including irregular-shaped vials and blood bags, among others. All these details and accessories must be thoroughly considered when selecting a centrifuge; otherwise, normal operation may be compromised.