Experts say: The price war in the laboratory centrifuge market has led to distorted development for companies. The only fundamental path for centrifuge enterprises to thrive is to pursue technological innovation and quality-driven growth.
  Research has found that the pace of scientific and technological development is constantly accelerating, and laboratory centrifuges are being used in an ever-wider range of applications. As a result, the technical requirements for laboratory centrifuges are becoming increasingly stringent. Existing centrifuge products are gradually failing to meet the demands of increasingly sophisticated separation and centrifugation experiments or production processes. This calls for centrifuge manufacturers to accelerate their pace of technological innovation in order to keep up with the needs of scientific and technological advancement. Given that orders and export volumes for these manufacturers are slowly declining, some companies have begun engaging in price wars—creating a fiercely competitive environment. Yet, this very situation presents an important opportunity for centrifuge manufacturers to reflect on their current practices and strategies.
  Domestic laboratory centrifuge technology itself started developing relatively late, and many of its production technologies still rely on imports from abroad, resulting in a very slow pace of development. Although in recent years, thanks to supportive national policies, Chinese research institutions have accelerated their efforts in R&D of laboratory centrifuge technologies, centrifuge companies themselves continue to invest very little in laboratory centrifuge technology. As a result, innovation in centrifuge technology remains sluggish, and the gap between domestic and international centrifuge technologies remains substantial.
  Some of China’s larger domestic laboratory centrifuge manufacturers, despite offering a diverse product lineup and maintaining relatively advanced technology, face a significant challenge: a shortage of well-trained centrifuge technical personnel. They lack the capacity to develop such talent internally and find it difficult to recruit externally. As a result, key technical positions at several major centrifuge manufacturers remain vacant year after year, hindering product development and preventing improvements in performance. These issues have become the biggest bottleneck restricting the growth of local centrifuge companies.
  The commonly used vibration detection method for laboratory centrifuges involves monitoring the amplitude of the centrifuge’s vibrations. Typically, limit switches or proximity switches are installed at specific locations on the centrifuge. When the vibration amplitude reaches a certain threshold, the limit switch is activated or the proximity switch detects a signal, causing the drive motor’s power supply to be cut off and the centrifuge to be braked. Under the combined action of gravity and braking force, the rotational speed and vibration amplitude of the centrifuge gradually decrease, thereby protecting the centrifuge from damage and preventing accidents. Due to... Laboratory centrifuge The radial impact force experienced under the same amplitude but different rotational speeds varies. The radial impact force caused by dynamic imbalance is directly proportional to the square of the rotational speed. Therefore, using the centrifuge’s amplitude as a protection criterion is insufficient. To effectively protect against dynamic imbalance in a centrifuge, the radial impact force acting on the shaft system should be used as the vibration protection criterion. According to Newton’s Second Law, the force acting on an object is proportional to its acceleration. Thus, the impact force can be measured by monitoring the acceleration of the centrifuge’s body. The centrifuge’s automatic controller can then regulate the centrifuge’s operation based on both the body’s acceleration and its rotational speed, thereby reducing impact forces and preventing accidents.
  In laboratory centrifuges, there are also floor-standing centrifuges equipped with refrigeration systems—low-speed, high-capacity refrigerated centrifuges that can process 6–12 liters of samples at a time. These centrifuges are widely used in bioengineering research and blood collection. In biological laboratories, these centrifuges are common equipment often employed for routine preliminary sample processing, such as the sedimentation of cells and larger cellular organelles. The acceleration and deceleration curves of these centrifuges are well-suited for density-gradient centrifugation as well. Additionally, some laboratory centrifuges offer wash-type rotor options, which can be used for cell separation. On laboratory centrifuges, swing-out rotors are frequently utilized; their baskets typically fit precisely into designated slots on the rotor frame.
   Laboratory centrifuge The principle behind centrifugation is that when an object undergoes uniform circular motion, it experiences an outward-directed centrifugal force. By placing a sample into a centrifuge rotor’s tube, the sample liquid will follow the tube’s uniform circular motion, generating an outward centrifugal force. Since different objects vary in mass, density, size, and shape, they will exhibit different sedimentation rates under the same fixed centrifugal field strength, thus enabling their separation from one another.