Rules and Precautions for Using Low-Speed Centrifuges
Release time:
2012-01-10
Overview:
Centrifuge Usage Guidelines:
1. When the centrifuge is in the pre-cooling state, the centrifuge lid must be closed. After the centrifugation is complete, once the rotor is removed, it should be inverted onto the experimental bench, and any remaining water inside the chamber should be wiped dry. The centrifuge lid should remain open.
2. During precooling, the rotor lid can be placed either on the centrifuge’s platform or on the lab bench. Under no circumstances should it be left floating loosely on the rotor without being securely tightened, as an accidental startup could cause the rotor lid to fly off and result in an accident!
3. After tightening the rotor cover, be sure to use your fingers to check for any gaps between the rotor and the rotor cover. If there is a gap, unscrew and retighten the cover until you confirm that there are no gaps before starting the centrifuge.
4. During the centrifugation process, operators must not leave the centrifuge room. In the event of an abnormal situation, operators must not turn off the power supply (POWER); instead, they should press the STOP button. Before pre-cooling, operators must complete the centrifuge usage log.
5. Do not use substandard or counterfeit centrifuge tubes, nor use centrifuge tubes that are aged, deformed, or cracked.
6. During holidays and in the evening, you may leave only after performing the routine safety check following the last use of the centrifuge.
7. If any machine malfunction or component damage occurs during instrument use, please contact us promptly.
Usage precautions:
Currently, electric centrifuges are commonly used in laboratories. Electric centrifuges rotate at high speeds, so it’s important to pay close attention to safety. In particular, you must take precautions against situations where the centrifuge might shift or move while operating—caused either by imbalance or by aging of the tube holders—leading to the centrifuge falling off the lab bench. Additionally, if the lid is not properly secured, the centrifuge tubes could rupture due to vibration, causing glass fragments to spin and fly out, potentially resulting in accidents. Therefore, when using a centrifuge, you must carefully follow these operational guidelines:
(1) The bottom of the centrifuge tube sleeve must be padded with cotton or a test-tube pad.
(2) If the electric centrifuge makes noise or the body vibrates, immediately disconnect the power supply and promptly troubleshoot the issue. (3) Centrifuge tubes must be placed symmetrically in their sleeves to prevent vibration of the machine body. If there is only one sample tube, the other sleeve should be filled with water of equal mass instead.
(4) When starting the centrifuge, you must first close the top cover before slowly starting it up.
(5) After the separation is complete, first turn off the centrifuge. Only after the centrifuge has come to a complete stop may you open the centrifuge lid and remove the sample. Do not use external force to forcibly stop the centrifuge from rotating.
(6) The centrifugation time is generally 1 to 2 minutes; during this period, the experimenter must not leave to attend to other tasks.
Many commonly used low-speed centrifuges have now made their way into laboratories. In corporate and academic research institutions, low-speed laboratory centrifuges with rotational speeds around 3,000 rpm have become quite prevalent—for example, the TD5GL benchtop filtration centrifuge, the TD5A benchtop low-speed centrifuge, and the TDZ6B low-speed benchtop centrifuge. These centrifuges feature a well-designed structure, a low center of gravity, and excellent safety and stability, making them increasingly popular for preliminary sample analysis in fields such as chemical engineering, food processing, and healthcare.