High-capacity centrifuge technology for separating blood cells
Release time:
2012-01-08
Overview:
(1) Materials and Reagents 1. Anticoagulants (1) Heparin: Heparin is a mucopolysaccharide containing sulfate groups; its sodium or potassium salts are commonly used. Heparin inhibits the conversion of prothrombin to thrombin, thereby suppressing fibrinogen's conversion into fibrin and preventing blood coagulation. The commonly used concentration of heparin solution is 1,000 U/ml; commercially available heparin typically ranges from 100 U to 126 U/mg. (2) Ethylenediaminetetraacetic acid (EDTA): This is a chelating agent. Prepare a 4% solution using physiological saline for later use. (3) Alsever’s Solution: The formulation is as follows: Sodium citrate (Na3C6H5O7·5H2O) 0.80 g, Citric acid 0.0325 g, Glucose 2.05 g, Sodium chloride 0.42 g, and add distilled water to make up to 100.00 ml. After thorough mixing and dissolution, sterilize under high-pressure steam at 114.3℃ for 10 minutes and set aside for future use. Alsever’s solution contains both sodium citrate as an anticoagulant and nutrients essential for cell survival; thus, it can serve both as an anticoagulant and as a preservation medium for blood cells. 2. Needles: Different needle sizes should be selected according to the animal species and the site of blood collection. Needles must be sterilized or disinfected before use. 3. Blood Collection Containers: Syringes or Erlenmeyer flasks, etc. 4. Animals for Blood Collection.
(2) Methods of Blood Collection 1. Blood Collection Techniques: The methods for blood collection vary among different animal species. For large animals such as horses, cattle, and sheep, blood is typically collected from the jugular vein; in pigs, it can be drawn from the jugular vein, the anterior vena cava, or the ear vein; in poultry, blood is collected from the subcutaneous veins under the wings or directly from the heart; in rabbits, blood is drawn from the heart or the ear vein; in dogs, it is collected from the jugular vein or the veins in the limbs; in guinea pigs, blood is obtained from the heart; and in mice, blood can be collected by tail amputation, by cutting the vessels beneath the armpits, or by enucleation. 2. Anticoagulation: The most critical aspect of blood collection is anticoagulation. The choice of anticoagulant method depends on the specific requirements and conditions of the experiment. The most commonly used methods are as follows: (1) Heparin Anticoagulation: During blood collection, add 15–20 U of heparin per milliliter of blood. Calculate the volume of blood to be collected, then add heparin at a concentration of 1,000 U/ml directly into the blood collection container. While collecting blood, gently shake the container continuously to ensure thorough mixing of the anticoagulant with the blood. For small volumes of blood or when collecting blood from small animals, you can directly use a syringe to draw a certain amount of heparin solution and then use it immediately to anticoagulate the blood. (2) EDTA Anticoagulation: Before blood collection, prepare a 4% EDTA solution using sterile saline. Then, according to the anticipated volume of blood to be collected, add 1–2 mg of EDTA per milliliter of blood into the collection container. Collect the blood while continuously shaking the container to ensure thorough mixing. (3) Glass Bead Method: Pre-wash an appropriate amount of glass beads (determined by the volume of blood to be collected), place them into the blood collection container, sterilize, and set aside for later use. During blood collection, continuously shake the collection bottle to keep the small glass beads rolling within the blood, mechanically removing fibrin and preventing blood coagulation. Although this method is relatively cumbersome, it has minimal impact on lymphocyte viability and reduces contamination by platelets. (4) ACD Blood Collection: Collect blood using ACD solution at a 1:1 ratio with the blood volume. Gently shake the collection bottle continuously during blood collection to ensure thorough mixing. In addition to its anticoagulant effect, ACD solution is often used for preserving red blood cells. Under normal storage conditions at 4°C, red blood cells preserved in ACD solution maintain their activity and characteristics unchanged for up to two weeks.
Red blood cell separation technology
(1) Materials and Reagents: 1. Anticoagulants such as heparin; 2. 3% Gelatin Solution: Take 3 g of gelatin and dissolve it in 100 ml of 0.9% sterile saline. Autoclave at 114.3°C for 10 minutes, then cool and store at 4°C. Before use, preheat at 37°C for 10 minutes. 3. Alsever’s Solution
(2) Operating Procedures: 1. Blood Collection and Anticoagulation—This yields red blood cells. Since the ratio of red blood cells to white blood cells is vastly different, white blood cells are usually present in small quantities and can be disregarded. 2. Depending on the intended use of the red blood cells, further processing may be required. For example, if counting red blood cells is necessary, they can be directly diluted and counted. If a complement-binding assay or other red blood cell lysis reaction is needed, the red blood cells must be thoroughly washed to remove plasma adhering to the surface of the red blood cell membrane. Typically, this is done by repeatedly washing with an isotonic diluent, followed by centrifugation at 2,000 rpm for 10 minutes, repeating the process 3 to 4 times. 3. If storage for future use is required, blood should be collected using ACD solution as an anticoagulant. After thorough mixing, the sample should be stored in a refrigerator at 4°C; it can be preserved for up to 2 weeks while still maintaining its activity.
Lymphocyte isolation techniques
(1) Materials and Reagents 1. There are two types of lymphocyte separation media: (1) Polysucrose-Iodixanol Solution: Polysucrose solution, commercially known as Ficoll, has a molecular weight of 400,000. It is commonly prepared as a 40 ± 1% (w/v) aqueous solution; it is also available in dry powder form. When using, prepare a 9% solution with distilled water. Iodixanol solution, Meglumine diatrizoate, commercially known as Vrografin, has the structural formula 3,5-diacetamido-2,4,6-triiodobenzoic acid 1-deoxy-methylamino-sorbitol. Its concentration is either 60% or 75%, and each vial contains 20 ml. It is commonly used for organ imaging in humans. To prepare a 33.9% iodixanol solution, take 20 ml of 60% iodixanol stock solution and add 15.38 ml of double-distilled water, resulting in a 33.9% iodixanol solution. Preparation of 1.077 ± 0.001 polysucrose-iodixanol solution: Mix 24 parts of 9% polysucrose solution with 10 parts of 33.9% iodixanol solution. If necessary, measure the specific gravity. For storage, filter through a G5 funnel to remove bacteria or sterilize at 114.3°C for 15 minutes, then store at 4°C. Generally, this solution can be stored for up to 3 months. If you need to prepare separation media with different proportions, use the following formula: where dm is the specific gravity of the separation medium, d1 and d2 are the specific gravities of the 9% polysucrose and 33.9% iodixanol solutions, respectively, and V1 and V2 are their respective volumes. For example, to prepare a separation medium with a specific gravity of 1.077, the ratio of 9% polysucrose to 33.9% iodixanol should be 100:46.3. (2) Iodixanol-Dextran Solution: Mix 10 parts of 34% iodixanol solution with 12.5 parts of 60% dextran solution to obtain a separation medium with a specific gravity between 1.07 and 1.09. Dispense into brown bottles and store at 4°C for later use. 2. 3% Gelatin Solution: Weigh 3 g of gelatin and dissolve it in 100 ml of sterile 0.9% saline solution. Sterilize at 114.3°C for 10 minutes, cool, and store at 4°C. Before use, preheat at 37°C for 10 minutes. 3. Hank’s Solution.
(2) Operating Procedure: 1. Collect anticoagulated blood and allow it to settle naturally. If the blood is from equine species, it can be directly placed upright in a test tube rack and allowed to settle naturally for 1 hour; then, carefully collect the upper-layer plasma. If the blood is from cattle or sheep, since their erythrocyte sedimentation rate is very slow, add an equal volume of 3% gelatin solution, mix thoroughly, and allow it to settle naturally for 1 hour before collecting the upper-layer plasma. 2. Centrifuge at 2,000 rpm for 10 minutes, then discard the supernatant. 3. Resuspend the pellet in Hank’s solution, and then centrifuge again at 2,000 rpm for 10 minutes. 4. Repeat step 3 once more, and then prepare a suspension of leukocytes using cell culture medium. This suspension contains the entire population of leukocytes, including granulocytes, lymphocytes, monocytes, and some red blood cells, and is suitable for leukocyte counting. 5. Transfer 2 ml of cell separation medium into a centrifuge tube. At the same time, use a capillary pipette to gently draw approximately 2 ml of plasma (the upper-layer plasma obtained after 1 hour of natural settling) and carefully layer it on top of the separation medium. Alternatively, anticoagulated blood can be added directly. 6. Centrifuge at 2,000 rpm for 20 minutes using a horizontal rotor centrifuge. After centrifugation, multiple layers will be visible: the bottom layer consists of red blood cells, the middle layer is the separation medium, and the top layer is the plasma. Between the plasma layer and the separation medium, there is a thin, dense, white layer—the mononuclear cell layer. 7. Use a capillary pipette to insert it into the mononuclear cell layer and carefully aspirate this layer into another test tube. 8. Wash the mononuclear cells with Hank’s solution, centrifuge, and finally adjust the cell suspension to an appropriate leukocyte concentration. If necessary, perform cell counting.
(3) Precautions: 1. When adding plasma or blood to the separation medium, proceed with caution and slowly, avoiding disturbance of the liquid layers or shaking. Alternatively, you can add the separation medium to the upper layer of the plasma. 2. Maintaining the viability of lymphocytes is crucial; therefore, in general, blood should be collected fresh and immediately subjected to separation. 3. The lymphocyte layer obtained after separation using the separation medium is actually a mononuclear cell layer, which includes monocytes but excludes granulocytes. If you wish to isolate pure lymphocytes, remove the monocytes according to the following procedure, or harvest the monocytes instead.
T lymphocyte isolation technique
(1) Principle: When a suspension of mononuclear cells is passed through a nylon wool column, B cells, plasma cells, monocytes, and certain helper cells are selectively retained on the nylon wool, while most T cells pass through the column. This method provides an effective way to obtain a T-cell-enriched cell population. (2) Materials and Reagents: 1. Nylon wool (Femwall Laboratories, LP-1 Leukoqak leukocyte Filters). 2. Beakers, aluminum foil, funnels, disposable gloves, etc. 3. Nylon wool column packing material and disposable syringes. 4. Obtain the mononuclear cell layer between the plasma and the density gradient medium after centrifugation of the naturally settled upper plasma layer using a Ficoll-Paque Plus density gradient solution.
(3) Operating Procedures 1. Cleaning and Drying of Nylon Fibers (1) Put on disposable gloves that have been washed to remove talc powder. Place the nylon fibers (1 or 2 packs, each containing 35 g) into a beaker, add distilled water or deionized water, cover the beaker with aluminum foil, and bring to a boil for about 10 minutes. (2) Allow the mixture to cool down to room temperature, then pour it into a funnel to let the excess water drain off. (3) Repeat steps (1) and (2) six times. (4) Spread the nylon fibers evenly onto a square tray lined with gauze. Dry them in an incubator at 37℃ for 2–3 days, then store them in a covered square tray. 2. Filling the Nylon Fiber Column (1) Take a 50 ml glass syringe, remove the plunger, and fit a rubber tube with a clamp onto the syringe’s tip. (2) Comb the nylon fibers and fold them appropriately to match the diameter of the syringe, then pack them into the syringe to a volume of about 20 ml. (3) Wrap the syringe filled with nylon fibers together with its plunger, and sterilize by autoclaving. 3. Cell Separation (1) Fix the syringe onto a stand, fill it with cell culture medium at 37℃, close the valve for a certain period, then open the valve to drain the cell culture medium several times to wash the nylon fibers, and finally close the valve again. (2) Dilute the cell suspension to be separated with pre-warmed culture medium to an appropriate concentration, approximately 5.00 × 10^7 cells/ml. (3) Pour the cell suspension into the syringe until it completely covers the nylon fiber column. Seal the syringe and incubate at 37℃ for 45 minutes to 1 hour. (4) Open the lower outlet and slowly allow the liquid to flow out drop by drop into a centrifuge tube. (5) Centrifuge the sample to obtain the desired T lymphocytes. (6) Close the lower outlet of the syringe, add 0.85% cold saline solution into the syringe, shake well, reattach the plunger, open the lower outlet, and forcefully expel the liquid from the syringe—this will release B lymphocytes, plasma cells, macrophages, and other cells adhering to the nylon fibers. (4) Precautions 1. In this separation method, some T lymphocytes may also become adsorbed onto the nylon fibers; the extent of adsorption depends on the quality of the nylon fibers as well as the tightness with which the column is packed. 2. The recovery rate of T lymphocytes using this method is approximately 20%–30%. 3. Used nylon fibers can be recycled: wash them with saline solution, then soak them overnight in 0.1 M HCl, and subsequently wash them again according to the previous procedure.
Monocyte isolation technology
(1) Iron Powder Adsorption Method 1. Materials and Reagents (1) Iron powder or carbonyl iron powder (Atomergic Chemetals), 99% purity, particle size less than 60 µm (Goodfellow Metals). (2) Strong magnet (horseshoe-shaped). (3) A small rod-shaped magnet (approximately 1 cm long). (4) Capillary tubes, etc. 2. Procedure (1) Weigh a certain amount of iron powder—typically 10 g—and wash it four times with 100 ml of physiological saline to remove any soluble toxic substances. As you decant the saline solution, use a strong magnet to hold the iron powder in place. (2) Suspend the iron powder in 50 ml of physiological saline. After thorough mixing, aliquot the suspension into 10 vials, seal the vial openings, and sterilize at 121°C for 20 minutes. Immediately after removal from the autoclave, gently shake each vial to prevent the iron powder from clumping; store the vials for later use. (3) Just before use, discard the physiological saline from each vial and add an appropriate volume of mononuclear cell suspension (3–5 ml, with a total cell count of 8 × 10^7 cells per vial). Incubate at 37°C for 45 minutes, shaking occasionally throughout the incubation period to keep the iron powder suspended. (4) Add a small magnetic rod to each vial, allowing it to attract the iron powder along with any cells adhering to it. (5) Discard the supernatant—the supernatant mainly contains lymphocytes—and centrifuge the remaining suspension to collect the cells. (6) Pour a certain volume of Hank’s solution into the vial containing the iron powder, shake vigorously, then use a strong magnet to adsorb the iron powder. After a few minutes, discard the liquid. (7) Centrifuge the liquid at 2,000 rpm; the pellet at the bottom of the tube will be the mononuclear cells.
(2) The glass slide adsorption method involves gently pouring the isolated single nucleated cells onto a sterile, clean glass dish and incubating at 37℃ for 30–40 minutes. Using a capillary pipette, carefully aspirate the cell suspension—this constitutes the lymphocytes. Rinse the dish with an appropriate amount of Hank’s solution to collect the mononuclear cell suspension.